Rockwell Automation Publication IASIMP-QS005H-EN-P - April 2016
71
GuardLogix® Controllers Logic Integration
Chapter 3
2. Browse to the ME Faceplate Files folder within the Guard I/O and SmartGuard Faceplate Files directory in the
toolkit.
If the toolkit has been loaded onto your personal computer, the hard drive path is
C:\Program Files\RA_Simplification\SafetyGuardLogix\Files\Guard IO and SmartGuard Faceplate Files\
ME Faceplate Files.
3. Choose the GuardIO_AOI file and click Import.
The Guard I/O Add-On Instruction appears in your project’s Add-On Instruction folder.
Create Controller Tags for Digital Guard I/O Faceplate
Prior to creating an instance of the digital GuardIO_AOI, you must create tags within the controller application. You
need to add these six tags for each of your digital Guard I/O modules, which you listed in your Safety Zone
Configuration worksheet from
Table 7 - Guard I/O Module Tags
Tag Name
Data Type
Tag Scope
[
ModuleName
]_MSG1
Message
Controller
[
ModuleName
]_MSG2
Message
Controller
[
ModuleName
]_ExtendedData
DINT[2]
Controller or program
[
ModuleName
]_InputData
DINT[2]
Controller or program
[
ModuleName
]_OutputData
DINT
Controller or program
[
ModuleName
]_ErrorCode
DINT
Controller or program