9
RF-TRMS
Troubleshooting
If your device is not charging or operating properly,
complete these troubleshooting steps.
To troubleshoot the power adapter:
1
Disconnect the power adapter from its power source.
2
Verify that the correct tip has been installed by checking
the Tip Compatibility table.
Caution:
Never force a tip into an electronic device.
3
Reconnect the power adapter. Check that all connections
are secure.
4
Plug the correct tip into your electronic device. The
device should begin charging regardless of whether it is
powered on or not.
If you are still experiencing problems, contact Rocketfish at
(800)620-2790.
Specifications
Input Voltage (AC): 100 - 240 Volts
Input Voltage (CLA): 12 - 16 VDC
Output Voltage: 16 - 24 Volts
Output Current: 5 Amps (max)
Output Power: 90 Watts
USB Output: 5 Volts @ 0 to 0.5 Amps
Unit dimensions: 6.3x 2.7x1.3 inches (160x69x34 mm)
Weight: 13.9 ounces (433.7g)
AC input cable: 5.6 ft (1.72 m)
DC power output cable: 5.6 ft (1.71 m)
CLA cable: 1.7 ft (.51 m)
Storage Temperature: -40 to 185°F (-40 to 85°C)
Содержание RF-PRACDC
Страница 12: ...12 ...
Страница 16: ...16 ...
Страница 44: ...44 ...
Страница 45: ...45 RF TRMS ...
Страница 46: ...46 ...
Страница 47: ...47 RF TRMS ...