Robustel GoRugged R3000-3P User Guide
29
3.13
Configuration -> Serial
This section allows users to set the serial parameters.
RS232 @ Serial
Item
Description
Default
Baud-rate
Select from “300”, “600”, “1200”, “2400”, “4800”, “9600”, “19200”, “38400”,
“57600” , “115200”and “230400”.
115200
Data bit
Select from “7” and “8”.
8
Parity
Select from “None”, “Odd” and “Even”.
None
Stop bit
Select from “1” and “2”.
1
Flow control
Select from “None”, “Software” and “Hardware”.
None
Protocol
Select from “None”, “Transparent”, “Modbus” and “AT Over COM”.
1.
Transparent: Router will transmit the serial data transparently without any
protocols.
2.
Modbus: Router will transfer the serial data into Modbus TCP protocol.
3.
AT Over COM: select to operate router via RS232 COM port. For example,
enter AT commands to router via RS232 COM port.
None
Mode @Transparent
Select from “TCP Server”, “TCP Client” and “UDP”.
TCP
Client
Local
Port
@Transparent
Enter the Local port for TCP or UDP.
0
Multiple
Server
@Transparent
Click “Add” button to add multiple server. You need to enter the server’s IP and
port, and enable or disable “Send data to serial”. If you disable “Send data to
serial”, router will not transmit the data from this server to serial port.
Note:
This section will not be displayed if you select “TCP server” in “Mode”.
None
show
Protocol
Advanced
@
Tick to enable protocol advanced setting.
Disable