background image

Specification:

Features:

Attention:

Operation:

Information for the Product user

Rated  Voltage: 240V~50Hz   

Output Voltage: 11.5V~30KHz  SELV equivalent

Model No.: 

                       LDT150N

Watt range: 

                       35W ~ 150W

Primary Amperage: 

          0.68A

Secondary Voltage: 

          11.5V

Secondary current: 

          3 x 4.2A

Ambient temperature:           -5°C~+40°C

Max. temperature of housing:  75°C

Dimensions:                             195mm x 50mm x 23mm

Wire length: 

Min: 30 cm from lighting unit to transformer

 

 

Max: 2 meters (use 1.5mm

2

 min cable size)

• 

Preheat function: protects against current surge.

• 

Secondary side short circuit protection: short circuit protection.

• 

Detect overload design: over load protection.

• 

Dimmable with most standard dimmers.

Electronic transformers must not be used in the same circuit as inductive loads 

(fluorescent lamps, discharge lamps, ventilating fans etc.) When switching Inductive 

loads, spikes of several thousand volts may result, causing damage to the transformer. 

Separate load circuits must always be provided. 

Under load on output may lead to lamp flickering, especially on dimmer circuits. 

Conventional and electronic transformers cannot be used with the same dimmer. 

The length of the secondary wire (12V side) must not exceed 2 meters.

The transformer is designed to be used exclusively with 12V halogen lamps. Soft start 

protects filaments and prolongs lamp life. In case of short circuit and overload, the unit 

shall automatically reset when fault is removed.

1. Please note the requirement to dispose of Waste Electrical & Electronic Equipment separately from household waste (WEEE 

    marked with crossed out wheelie bin symbol). 

2. Please consider your role in contributing to re-use and recycling by returning this product at end of life to a collection centre 

    for waste electrical equipment or a Civic Amenity site, or to a retail outlet from which you are purchasing a replacement.

3. This equipment may contain substances that are hazardous to health and the environment if disposed of  carelessly.  It is 

    important that it is separated from normal household waste and recycled in the WEEE chain

4. The “crossed out wheelie bin symbol” on a product indicates this equipment must not be disposed of in normal household 

    waste, but should be disposed of according to local WEEE regulations

Issue 1 110410 

LDT150N

150W Electronic Transformer 

Please read instructions before commencing installation and 

retain for future reference.

The Installation must be carried out by an electrician

LED Group 

 

 

Western Retail Park 

         Tel: +353 1 7099000 

Nangor Road 

 

         Fax: +353 1 7099060

Dublin 12  

 

         Email: [email protected] 

Ireland   

 

         Website: www.led.ie

I

SO 9001:2008

Q UAL IT Y ASSU RED CO MPANY

Page 1