Diagnostics
56
8
CODES
DESCRIPTION
Warning (u)
Error (E)
478
High hot water delivery temperature
Check cleanliness of water filters.
Check water flow.
Reset is automatic when the triggering
condition ceases.
NA
480
80
Incomplete functional parameters
Invalid configuration parameters
Contact the TAC.
481
Invalid bank 1 parameters
Reset is automatic when the triggering
condition ceases.
Contact the TAC.
482
Invalid bank 2 parameters
Reset is automatic when the triggering
condition ceases.
Contact the TAC.
485
Invalid module type configuration
parameters
NA
Contact the TAC.
486
ROM board fault
NA
Contact the TAC.
487
pRAM board fault
NA
Contact the TAC.
488
xRAM board fault
NA
Contact the TAC.
489
Registers board fault
NA
Contact the TAC.
490
Outdoor temperature probe fault
NA
The reset may be done following one of procedures shown in
Paragraph 6.6.1
If the code persists, shows up again or in case of doubt, contact
the TAC.
491
Electronic board fault
NA
Contact the TAC.
492
Weather probe fault (connected to
AUX 1)
Reset is automatic when the triggering
condition ceases.
NA
493
Weather probe fault (connected to
AUX 2)
Reset is automatic when the triggering
condition ceases.
NA
495
Auxiliary boiler fault
NA
The reset may be done following one of procedures shown in
Paragraph 6.6.1
If the code persists, shows up again or in case of doubt, contact
the TAC.
NA: Not Applicable
8.2
BOILER BOARD CODES
Table 8.3
Operative codes
Code
Icon
Fault
Intervention
E01
RESET
Flame lockout
Make sure that the boiler and gas meter gas valves are open.
Press the reset button (detail H Figure 1.3
p. 10). As soon as the error code
disappears from the display, the boiler will restart automatically.
If the code persists, shows up again or in case of doubt, contact the TAC.
E02
RESET
Safety thermostat (95 °C)
Press the reset button (detail H Figure 1.3
p. 10). As soon as the error code
disappears from the display, the boiler will restart automatically.
If the code persists, shows up again or in case of doubt, contact the TAC.
E03
RESET
Flue safety thermal fuse (102 °C)
Contact the TAC.
E04
Low system water pressure
If the system pressure is below 1,5 bar fill the system as described in Paragraph
If the code persists, shows up again or in case of doubt, contact the TAC.
E05
SERVICE
Heating probe
Contact the TAC.
E06
SERVICE
DHW probe
Contact the TAC.
E15
SERVICE
Return probe
Contact the TAC.
E16
SERVICE
Blower
Contact the TAC.
E18
SERVICE
Low water flow
Contact the TAC.
E21
SERVICE
Generic internal electronic board error
Cut off power supply from the main switch and then restore it. As soon as the
error code disappears from the display, the boiler will restart automatically.
If the code persists, shows up again or in case of doubt, contact the TAC.
E22
SERVICE
Parameter programming request
Cut off power supply from the main switch and then restore it. As soon as the
error code disappears from the display, the boiler will restart automatically.
If the code persists, shows up again or in case of doubt, contact the TAC.
E35
RESET
Parasitic flame
Press the reset button (detail H Figure 1.3
p. 10). As soon as the error code
disappears from the display, the boiler will restart automatically.
E40
SERVICE
Supply voltage
Contact the TAC.
Table 8.4
Active functions signaling codes
Code
Function
Intervention
F08
Heating antifreeze function activated
Wait until the operation is completed.
F09
DHW antifreeze function activated
Wait until the operation is completed.
F28
Anti-legionella
Wait until the operation is completed.
F33
System air purge cycle in progress
Wait until the operation is completed.