3.5 Electrical Setup
Power Supply :
Power and communication are established with the Wrist Camera via the high-flex device cable. The cable provides a 24 V power supply to the Wrist
Camera and enables USB 2.0 communication with the Universal Robots controller.
Follow these steps to correctly wire the Wrist Camera (or the camera and 2-Finger Gripper combo) to a Universal Robots controller :
With the controller turned off, connect the red (24 V) and black (0 V) wires of the device cable as shown in Figure 3.5.1. Use any available 24 V
and 0 V.
Figure 3.5.1: Power supply wiring on CB3.1 Universal Robots controller.
Connect the 4 ports USB hub (ACC-USB-4-HUB) inside the robot controller.
Connect the Wrist Camera's USB connector in the 4 ports USB hub.
Connect the licence USB dongle (ACC-USB-DONGLE) in the 4 ports USB hub.
Figure 3.5.2: 4 ports USB hub connection.
Wrist Camera grounding is optional and is done via the robot ground. The camera's indexing pin (dowel) is the ground connector.
Cable Management
2-Finger Gripper
If mounting a 2-Finger Gripper on the Wrist Camera, the Camera replaces the gripper's coupling. Therefore, only the Wrist Camera's device
cable is required to provide power and communication to both the camera and the gripper. The wiring for setups including only the camera or
both the camera and the gripper is the same.
Cable management
Use proper cabling management. Be sure to leave enough excess cable to allow full robot movement without pulling out the connectors.
Always protect the controller-side (robot side) connector of the cable with a strain relief cable clamp.