5. Maintenance and Inspection
92
●
Small and Medium Two-finger Type (GRS/GRM)
1) Use a flathead screwdriver to turn the opening/closing
screw on side cover L to move the fingers toward the
stroke center.
2) Spray grease in the gap (on the steel balls) between the
finger and finger guide (4 locations; keep the spray time
to a maximum of 1 second at each location). After
spraying, turn the opening/closing screw to move the
fingers back and forth several times to spread the grease
evenly. Remove excess grease or grease spatters in
surrounding areas.
3) Spread out the grease evenly on the fingers and finger
guides with hand (for rust prevention treatment)
Caution:
• Never use fluorine grease. If fluorine grease is mi
xed with lithium grease, the lubricating function
of grease will drop and the machine may suffer damage due to increased friction.
• Do not use spray oil. Be sure to use spray
grease. Keep the spray time to a maximum of 1
second, and never spray more than once. If too much
grease is applied, excess grease may flow
into the electronic components and cause malfunction.
• In case the grease got into your eye, immediat
ely go to see the doctor to get an appropriate care.
After finishing the grease supply work, wash your hands carefully with water and soap to rinse the
grease off.
Finger guide
Grease application
Open/close screw
Finger
Содержание GR3LM
Страница 2: ......
Страница 4: ......
Страница 70: ...2 Installation 64 Shaft bracket Flange bracket Shaft bracket Flange bracket φ φ φ φ φ φ φ φ 2 GRS 3 GRM ...
Страница 71: ...2 Installation 65 4 GRHM Shaft bracket Flange bracket 5 GRHB Flange bracket Shaft bracket ...
Страница 74: ...2 Installation 68 depth 8 depth 8 GRS GRM ...
Страница 77: ...2 Installation 71 depth 5 depth 6 φ φ GR3SS GR3SM ...
Страница 78: ...2 Installation 72 GR3LS GR3LM ...
Страница 127: ......