2. Installation
79
To achieve higher installation precision and repeatability for finger attachments, it is recommended that
each finger attachment be positioned by sandwiching the attachment between the positioning pin and the
side face of the finger, as illustrated below.
●
GR3LS/GR3LM
Positioning pin
Open
/close
directions
Shoulder contact surface
Positioning in vertical directions
Vertical directions
Shoulder contact surface
Positioning in vertical directions
Finger attachment
Finger
Stopper contact surface
Positioning in longitudinal
directions
Ho
me
re
tu
rn
d
ire
ction
(O
ffs
et
)
During home return, the fingers bounce
outward by 1 degree after reaching the
home position, and then return to the
home position.
(Pay attention not to allow the finger attachments
and tightening bolts to contact the front cover.)
Longitudinal directions
Positioning in longitudinal
directions
Caution:
• When installing or removing the attachment to/from the finger, tighten the screw while holding the
attachment with a spanner wrench, etc., so that the guide will not receive any load or impact.
Содержание GR3LM
Страница 2: ......
Страница 4: ......
Страница 70: ...2 Installation 64 Shaft bracket Flange bracket Shaft bracket Flange bracket φ φ φ φ φ φ φ φ 2 GRS 3 GRM ...
Страница 71: ...2 Installation 65 4 GRHM Shaft bracket Flange bracket 5 GRHB Flange bracket Shaft bracket ...
Страница 74: ...2 Installation 68 depth 8 depth 8 GRS GRM ...
Страница 77: ...2 Installation 71 depth 5 depth 6 φ φ GR3SS GR3SM ...
Страница 78: ...2 Installation 72 GR3LS GR3LM ...
Страница 127: ......