5. Maintenance and Inspection
98
2) Turn the opening/closing screw to move the fingers to their stroke ends on the closed side.
3) Use a grease syringe to charge grease from the opening on the right side so as to coat the feed
screw with grease. After the feed screw has been coated with grease roughly, turn the
opening/closing screw to move the fingers back and forth several times to spread grease evenly.
4) Turn the opening/closing screw to move the fingers to their stroke ends on the open side.
5) Use a grease syringe to charge grease from the opening on the bottom face of the guide base so as
to coat the feed screw with grease. After the feed screw has been coated with grease roughly, turn
the opening/closing screw to move the fingers back and forth several times to spread grease evenly.
6) Install and securely affix side cover R.
Caution:
• Never use grease other than synthetic poly-
α
olefin grease. If synthetic poly-
α
olefin grease is
mixed with other type of grease, not only the mixed grease will lose its intended function, but the
actuator may also suffer damage depending on the situation.
• In case the grease got into your eye, immediat
ely go to see the doctor to get an appropriate care.
After finishing the grease supply work, wash your hands carefully with water and soap to rinse the
grease off.
Содержание GR3LM
Страница 2: ......
Страница 4: ......
Страница 70: ...2 Installation 64 Shaft bracket Flange bracket Shaft bracket Flange bracket φ φ φ φ φ φ φ φ 2 GRS 3 GRM ...
Страница 71: ...2 Installation 65 4 GRHM Shaft bracket Flange bracket 5 GRHB Flange bracket Shaft bracket ...
Страница 74: ...2 Installation 68 depth 8 depth 8 GRS GRM ...
Страница 77: ...2 Installation 71 depth 5 depth 6 φ φ GR3SS GR3SM ...
Страница 78: ...2 Installation 72 GR3LS GR3LM ...
Страница 127: ......