5. Maintenance and Inspection
94
Guide cover L affixing screw
Open/close screw
5.5 Feed Screw Small and Medium Two-finger Type (GRS/GRM)
[1] Applicable Greases
IAI uses the following grease in our plant.
Idemitsu Kosan
Daphne Eponex Grease No. 2
Use lithium spray grease during maintenance. Take note that grease should not be sprayed for more
than 1 second.
WAKO CHEMICAL, LTD.
Spray Grease No. A161 or equivalent
[2] How to Apply Grease
1) Remove the screws affixing side cover R and side cover L (countersunk head screw M2.6 × 6).
Remove side cover R.
Separate side cover L from the gripper frame. (The cover is still connected via internal cables. Do not
pull the internal cables.)
2) Turn the opening/closing screw on side cover L
to move the fingers toward the closing side until
the guide cover R/L affixing screws are visible.