background image

Models 

9801

i

9815

i

and 

9820

i

Quick Start Installation Manual

111-321D

Installation DOs and DON’Ts

DO
• 

Shut off all power to system before installing.

• 

Read entire manual before installing.

• 

Make sure that all wiring conforms to
national and local codes.

DO NOT
• 

Install on voltages greater than 30 VAC.

• 

Short jumper across terminals on the gas
valve or at the system control.

• 

Connect ground to any terminal in
this unit.

• 

Install on outside walls or in direct sunlight.

Select location for installation.

1

Open the case with a screwdriver. Place
in slot and gently pry forward at all four
locations.

2

Mark mounting hole locations on wall.

3

Drill  

3

/

16

” holes at marked locations on

wall. Insert plastic anchors into holes.

4

Align unit base over plastic anchors
embedded in wall and secure with the
screws provided.

5

Connect wiring between unit and 
furnace. For Model 9801i (1H/1C 
furnace applications).

6

Cut

out

opening

a

b

1/4"

1-1/2"

1"

1

2

3

4

Mark mounting hole 
locations on wall using 
unit base as template.

Drill 3/16  holes

a

b

Press anchors into holes until flush.

Y1

R

C

E/W1

H O B G

Thermostat

C

- 24VAC Common

R

- 24VAC

Y1

- 1st stage cooling

E/W1 - 1st stage heating
O

- Not used

B

- Not used

G

- Fan

H

- Humidification

TERMINAL DESIGNATIONS

C

C

H

R

Y

W

G

B

O

Note: To avoid electrical problems, use the system transformer for both

the thermostat and humidifier.

9801

i

Humidifier

Equipment Wiring 
Terminals
Please refer to furnace 
installation manual for 
proper terminations

Remove 1/4” of insulation
from end of each wire

DELUXE
PROGRAMMABLE
THERMOSTATS

Отзывы: