Robertshaw 84370 Series Скачать руководство пользователя страница 1

 

1

 

TABLE 1 

SUFFIX DESCRIPTION RESET 

Direct Acting - Vents on Increase 

Auto 

Reverse Acting - Closes Vent on 
Increase 

Auto 

Direct Acting - Vents on Increase  

Manual 

 

TABLE 2 

SUFFIX 

SETPOINT RANGE - psi (bar) 

5 to 25 (.345 to 1.724) 

15 to 65 (1.034 to 4.482) 

 

 

Sales Manual Section 335 

PRODUCT SPECIFICATION 84370 SERIES 

 

Pressure Sensor 

No. 84370-Series 

84370-A, C Series 

84370-B Series 

Vents on Increase 

Closes Vent on Increase 

 (Direct-Acting) 

(Reverse-Acting) 

 

J.I.C. Symbols 

ORDERING INFORMATION 

Specify: 

1.   Model 

2.   Control Pressure - If not specified, sensor is set 

using 30 psi (2.068 bar). 

3.   Setpoint - If not specified, set at minimum. 

4.   Differential (Automatic Reset models only) - If 

not specified, set at standard. 

5.   Tagging Information. 

See Page 2 for SPECIFICATIONS. 

Form No. P-2347, Rev. B 

 

GENERAL DESCRIPTION 

 

The patented* No. 84370-Series Pressure Sensor 

contains a weather-proof, snap-acting valve operated 

by pressure variation around the integral sensing 

element. Depending upon model used, it vents or 

blocks a pneumatic signal when the setpoint is 

reached and is available with either automatic or 

manual reset. The sensor has adjustable differential 

(auto reset versions only) and setpoint, provision for 

piped vent operation, and is field reversible. Setpoint 

is virtually unaffected by control pressure change or, 

in the case of piped vent versions, vent backpressure 

change. In the auto reset versions, reset differential 

can be changed without shifting setpoint. 

For correct operation, control pressure must be 

provided thru a .032" (.81 mm) diameter or smaller 

orifice. 

 

*

Patent 3.986,524

 

 

 

MODELS AVAILABLE 

84370 - 

Table 1 

 Table 2 

 

Содержание 84370 Series

Страница 1: ...ging Information See Page 2 for SPECIFICATIONS Form No P 2347 Rev B GENERAL DESCRIPTION The patented No 84370 Series Pressure Sensor contains a weather proof snap acting valve operated by pressure variation around the integral sensing element Depending upon model used it vents or blocks a pneumatic signal when the setpoint is reached and is available with either automatic or manual reset The senso...

Страница 2: ...ene Diaphragms and Gasket Neoprene and Buna N on Nylon Control Pressure 20 to 60 psi 1 379 to 4 137 bar Maximum Control Pressure 75 psi 5 171 bar Maximum Ambient Temperature 160 F 71 1 C Repeatability 1 of setpoint Mounting Panel or Manifold Approximate Shipping Weight 2 1 4 lb 1 02 Kg Control Medium Air Natural Gas Nitrogen Filtration Minimum 25 microns Moisture Pressure Dewpoint 15 F 8 3 C less ...

Страница 3: ...er months Vent openings should have fittings installed turned down The 1 8 27 NPT connection can be used for piped vent operation if gas is used CONNECTIONS The sensor has three 1 8 27 NPT connections one for control pressure one for vent pressure and one for case relief pressure CAUTION Do not pipe or plug case relief connection The vent pressure connection from the sensor cannot be used as a sup...

Страница 4: ...ent screw The inlet port pressure is thus vented past the diaphragm seat and out the vent port With the lowering of process pressure below set point the range spring forces the stem and sleeve toward the bellows head In the automatic reset models the bellows head is stationary at this time against the reset and differential screw This stationary position allows the sleeve to seat itself on the O r...

Страница 5: ...below Direct and Reverse Acting Remove remaining diaphragm clamp and diaphragm Remove retaining ring detail 32 spring detail 34 and sleeve Remove defective O ring detail 31 and replace Reassemble sleeve spring detail 34 and retaining ring detail 32 To replace O ring detail 29 in valve housing remove retaining ring detail 28 and defective O ring detail 29 Replace O ring then retaining ring To repla...

Страница 6: ... reverse acting units until the valve closes then reverse direction and turn screw until valve snaps open and vents 5 Check operation and trim as necessary 6 Replace the cap screw DIFFERENTIAL Applicable to Auto Reset versions only CAUTION Sensor will not vent if differential adjustment screw is turned clockwise to its maximum insertion into the valve housing Do not set differential below minimum ...

Страница 7: ... 26 1 Pressure Assembly See Tabulation 27 1 Differential Adjustment Screw Not shown See Tabulation 28 1 Retaining Ring Included in Detail 15 36605 B2 29 1 O Ring Included in Detail 15 36240 V0016 30 1 O Ring Included in Detail 15 36243 V0012 31 1 O Ring 36240 V0010 32 1 Retaining Ring Not Used 33 1 Sleeve 33974 A2 34 1 Spring 33975 A1 TABULATION MODEL NO DET 5 DET 17 DET 18 DET 20 DET 26 DET 27 84...

Страница 8: ...stang Drive Maryville Tennessee 37801 Phone 865 981 3100 Fax 865 981 3168 http www robertshawindustrial com Exports Invensys Appliance Controls 1701 Byrd Avenue P O Box 26544 Richmond Virginia 23261 6544 Phone 804 756 6500 Fax 804 756 6561 Q 3592 4 03 Printed in U S A ...

Отзывы: