Robertshaw 8000 Series Скачать руководство пользователя страница 1

INSTALLATION DATA

8000 SERIES

SINGLE LEVEL PRESSURE SWITCHES

The Robertshaw® 8000 Series Single Level Pressure Switches will 
replace several models of Robertshaw switches used on sump pumps 

and other similar appliances. A typical application on a sump pump unit 
is shown at right. The switch operates as an automatic control device 

which turns the pump motor on when the water level rises and turns it 

off when the level falls.

ELECTRICAL  RATING

15 Amps - 125-250V AC
1/2 h.P. - 125-250V AC
UL and CSA listed

CAUTION

ThIS DEVICE ShOULD BE INSTALLED BY A QUALIFIED SERVICE 
TEChNICIAN WITh DUE REGARD FOR SAFETY AS IMPROPER 
INSTALLATION COULD RESULT IN A hAZARDOUS CONDITION.

INSTALLATION INSTRUCTIONS

1.  Disconnect POWER SUPPLY.

2.  Remove old switch and note terminal wiring before disconnecting 

 

 leads.

3.  Attach leads to new switch and install switch in operating position.

NOTE:

 Some applications require the switch to be submerged in liquid 

(sump pumps). A gasket is used to seal the terminal area from the  

liquid. When replacing this type switch use new neoprene gasket 

 

supplied with switch. Be certain gasket is located on same side of 
switch as old gasket.

4.   Secure  switch firmly in place and reassemble any other parts if 

 

  their removal was required.

Figure 1 - Flat Opening 

Figure 4 - SPST With Ground Terminal

Figure 2 - Tubing Opening

Figure 5 - Standard SPDT

Figure 3 - Standard SPST