Roberts Gorden GordonRay BH-100 Скачать руководство пользователя страница 1

Fuel Conversion Kit Instructions

BH-40
BH-60
BH-80
BH-100

BH-125
BH-150
BH-175
BH-200

P/N 270101NA  Rev. A  11/99

Roberts-Gordon

1250 William Street
P.O. Box 44
Buffalo, New York 14240-0044
Telephone:  716.852.4400
Fax:  716.852.0854
Toll Free: 800.828.7450

http://www.rg-inc.com

Roberts-Gordon Canada Inc.

241 South Service Road West
Grimsby, Ontario L3M 1Y7 Canada
Telephone:  905.945.5403
Fax:  905.945.0511
Toll Free:  800.663.9025

© Copyright  1999  Roberts-Gordon

DO NOT store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.

FOR YOUR SAFETY

If you smell gas:

1. Open windows.
2. DO NOT try to light any

appliance.

3. DO NOT use electrical

switches.

4. DO NOT use any telephone

in your building.

5. Leave the building.
6. Immediately call your local

gas supplier after leaving
the building. Follow the gas
supplier’s instructions.

7. If you cannot reach your gas

supplier, call the Fire
Department.

GordonRay  BH

®

WARNING

Installation must be done by a contractor qualified
in the installation and service of gas-fired heating
equipment or your gas supplier.

Improper installation, adjustment, alteration, service
or maintenance will result in death, injury or property
damage. Read the installation, operation and service
manual thoroughly before installing or servicing
this equipment.

Installer

Please take the time to read and understand

these instructions prior to any installation.

Installer must give a copy of this manual to the owner.

Owner

Keep this manual in a safe place to provide your

serviceman with information should it become

necessary.

Содержание GordonRay BH-100

Страница 1: ... DO NOT use any telephone in your building 5 Leave the building 6 Immediately call your local gas supplier after leaving the building Follow the gas supplier s instructions 7 If you cannot reach your gas supplier call the Fire Department GordonRay BH WARNING Installation must be done by a contractor qualified in the installation and service of gas fired heating equipment or your gas supplier Impro...

Страница 2: ......

Страница 3: ...al Conversions Only FIGURE 2 4 Contents of Fuel Conversion Kits Propane to Natural 4 Warnings 5 FUEL CONVERSION INSTRUCTIONS 6 Step 1 FIGURE 3 6 Step 2 FIGURE 4 7 Step 3 FIGURE 5 8 FIGURE 6 9 Step 4 9 FIGURE 7 10 Step 5 FIGURE 8 11 Step 6 11 CLEARANCES TO COMBUSTIBLES 12 FIGURES 9 10 11 13 FIGURES 12 13 14 14 FIGURES 15 16 17 15 OPERATION AND MAINTENANCE 16 Sequence of Operation 16 Pre Season Main...

Страница 4: ......

Страница 5: ...ided in these instructions For additional copies of the GORDONRAY BH Installation Operation and Service Manual please contact Roberts Gordon Questions Comments or Suggestions Please direct any questions comments or suggestions to In the United States Roberts Gordon 1250 William Street P O Box 44 Buffalo New York 14240 0044 USA Telephone 716 852 4400 Toll Free 800 828 7450 Fax 716 852 0854 Home Pag...

Страница 6: ...o Us Important Notice In Canada The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CAN1 B149 1 and 2 installation codes WARNING Use only genuine ROBERTS GORDON conversion kits Failure to follow these instructions will result in death injury or property damage WARNING Service and an...

Страница 7: ...00 90032600 BH200NP 200 91910420 91039400 90032600 FIGURE 1 Conversion Kit Installation in Regulator This appliance has been converted to _______ fuel Orifice __________________________________ Manifold Pressure __________________________ Input ____________________________________ Cet appareil a ete converti au ________________ Injecteur ________________________________ Pression a la tubulure d al...

Страница 8: ...STEEL WHITE FIGURE 2 Conversion Kit Installation in Regulator This appliance has been converted to _______ fuel Orifice __________________________________ Manifold Pressure __________________________ Input ____________________________________ Cet appareil a ete converti au ________________ Injecteur ________________________________ Pression a la tubulure d alimertation ____________ Debit calorifiq...

Страница 9: ...or property damage Explosion Hazard Turn off the gas supply to the heater before perform ing any service or mainte nance Failure to follow these instructions will result in death injury or property damage WARNING Health Hazard Gasket material may be harmful if inhaled Gasket material may also be irritating to the skin eyes and respiratory tract Failure to follow these instructions will result in i...

Страница 10: ...ansition tube using a 1 2 wrench f Remove the burner Refer to Page 6 Figure 3 g Save the Gasket P N 02568200 or re install a new one after conversion Step 1 Fuel Conversion Instructions WARNING Burner is secured to transition tube by Bolts and Lockwashers Upon removal of Bolts Burner is free from Transition Tube and will fall if not supported Failure to follow these instructions will result in dea...

Страница 11: ...er assembly Unplug the blower using a 1 4 nut driver or a phillips screwdriver remove the 7 screws and the door assembly and set aside Refer to Page 7 Figure 4 Step 2 FIGURE 4 Burner External View Install Label Here P N 91039400 Blower Screws 7 Blower Plug Door Assembly Control Side Door Screws 2 ...

Страница 12: ...ds of the replacement orifice Be aware that over application of sealant may cause blockage of the orifice Insert and tighten the replacement orifice CAUTION Do not over tighten the gas orifice The torque value for the gas orifice is 15in lbs contact your factory representative for more details c Replace the burner cup Insure large external tooth washer is in place then tighten the burner cup d Rep...

Страница 13: ...comes on adjust the regulator by turning the adjusting screw to set the pressure to Natural 3 5 w c inches water column Propane 10 5 w c d Secure power and gas e Remove tap and replace plug and adjusting screw Step 4 Fuel Conversion Instructions FIGURE 6 Pressure Regulator 9 WARNING Bolts must be torqued to 120 in lbs as stated below to secure transition tube to burner Transition tube will separat...

Страница 14: ... 4 5 6 6 5 4 3 2 1 0 1 2 3 4 5 6 Natural Propane 10 5 3 5 Top View of Heater FIGURE 7 Manometer Reading Manometer Reading Electrical Shock Hazard Disconnect electrical power before installation or service Failure to follow these instructions will result in death or electrical shock WARNING ...

Страница 15: ...his appliance has been converted to _______ fuel Orifice __________________________________ Manifold Pressure __________________________ Input ____________________________________ Cet appareil a ete converti au ________________ Injecteur ________________________________ Pression a la tubulure d alimertation ____________ Debit calorifique __________________________ Printed in the U S A Imprimé aux ...

Страница 16: ... be posted to specify the maximum permissible stacking height to maintain required clearances from the heater to the com bustibles Signs must be posted adjacent to the heater thermostat In the absence of a thermostat signs must be posted in a conspicuous location Consult local Fire Marshal Fire Insurance Carrier or other authorities for approval of proposed instal lation when there is a possibilit...

Страница 17: ... 52 14 BH 60 6 20 58 20 BH 80 6 22 63 22 BH 100 6 26 67 26 BH 125 6 29 71 29 BH 150 6 33 77 33 BH 175 8 38 87 38 BH 200 8 38 87 38 Canada Metric cm Model A B C D BH 40 15 58 127 58 BH 60 15 69 135 69 BH 80 15 76 150 76 BH 100 15 84 163 84 BH 125 15 89 168 89 BH 40 15 99 180 99 BH 175 20 109 191 109 BH 200 20 109 191 109 Canada Metric cm Model A B C D BH 40 15 23 127 89 BH 60 15 23 135 99 BH 80 15 ...

Страница 18: ...H 80 7 52 53 17 BH 100 9 59 60 17 BH 125 9 63 64 17 BH 150 11 66 67 17 BH 175 11 70 80 17 BH 200 11 70 80 17 Canada Metric cm Model A B C D BH 40 18 18 107 104 BH 60 18 18 119 117 BH 80 18 18 135 132 BH 100 23 18 152 150 BH 125 23 18 163 160 BH 150 28 18 170 168 BH 175 28 18 178 173 BH 200 28 18 178 173 Canada Metric cm Model A B C D BH 40 BH 60 15 74 142 64 BH 80 15 84 160 76 BH 100 15 91 168 81 ...

Страница 19: ... 18 BH 60 14 18 18 BH 80 14 24 18 BH 100 20 24 18 BH 125 20 24 18 BH 150 20 30 18 BH 175 20 30 18 BH 200 20 30 18 Canada Metric cm Model A B C D BH 40 BH 60 18 18 119 91 BH 80 18 18 135 112 BH 100 18 18 152 124 BH 125 18 18 163 140 BH 150 18 18 170 147 BH 175 18 18 180 160 BH 200 18 18 180 160 Canada Metric cm Model A B C D BH 40 15 58 127 58 BH 60 15 69 135 69 BH 80 15 76 150 76 BH 100 15 84 163 ...

Страница 20: ...tion of the heater annual inspections by a contractor qualified in the installation and service of gas fired heating equipment and owner are essential Before every heating season a contractor quali fied in the installation and service of gas fired heating equipment must perform a thorough safety inspection of the heater For best perfor mance the gas electrical thermostat connec tions tubing ventin...

Страница 21: ...ediately remove objects in violation of the clearances to combustibles Make sure there is no dirt sagging cracking or distortion Do not operate if there is sagging cracking or distortion Make sure reflectors are correctly overlapped Clean outside surface with a damp cloth Venting must be intact Using a flashlight look for obstructions cracks on the pipe gaps in the sealed areas or corrosion Do not...

Страница 22: ...d ceramics excessive carbon residue or erosion of the electrodes The electrode gap should be 125 32 mm There should be no exposed wire or damage to the thermostat Make sure the heater is hanging securely Look for signs of wear on the chain or ceiling Do not operate if the heater is hanging insecurely The grille must be securely attached Check that side reflector extensions are installed correctly ...

Страница 23: ...u need replacement parts or have additional questions call or write Roberts Gordon U S A 1250 William Street P O Box 44 Buffalo New York 14240 0044 Telephone 716 852 4400 Fax 716 852 0854 Canada 241 South Service Road West Grimsby Ontario L3M 1Y7 Telephone 905 945 5403 Fax 905 945 0511 On the web at www rg inc com Roberts Gordon s liability and your exclusive remedy under this Warranty or any impl...

Отзывы: