Robe 55AT Скачать руководство пользователя страница 1

Version 2.1

Содержание 55AT

Страница 1: ...Version 2 1 ...

Страница 2: ... the front lens 12 5 DMX Protocol 13 6 Controller mode 16 6 1 DMX addressing 16 6 2 Remotely controllable functions 16 7 Stand alone mode 17 8 Control menu map 18 9 Functions of the control panel 21 9 1 Fixture Address 21 9 2 Slave control 21 9 3 Fixture informations 21 9 4 Personality 23 9 5 Lamp On Off 23 9 6 Manual mode 24 9 7 Test sequences 24 9 8 Stand alone setting 24 9 9 Reset functions 25 ...

Страница 3: ... This device falls under protection class I The power plug must only be plugged into a protection class I outlet Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged by sha...

Страница 4: ... firmly closed and all screws are tightly fastened The lamp must never be ignited if the fresnel lens or any housing cover is open as discharge lamps may explose The maximum ambient temperature must never be exceeded CAUTION The lens has to be replaced when it is obviously damaged so that its function is impaired e g due to cracks or deep scratches Operate the device only after having familiarized...

Страница 5: ... Front cover 2 Rear cover 5 Fresnel lens 3 Adjusting screw Control panel 1 Display 2 Mode button 3 Enter button 4 Up button 5 Down button Rear side 1 Control board 2 3 Fans 4 DMX output 5 DMX input 6 Lamp cover 7 Fuse holder 8 Power switch 9 Power cord ...

Страница 6: ...in one time and then confirming with the Enter button Do not operate this fixture with opened housing cover 4 2Lamp adjustment The lamp holder is aligned at the factory Due to differences between the lamps fine adjustment may improve light performance Strike the lamp cancel all effects open the shutter and set the dimmer intensity to maximum and focus the light on a flat surface wall or use functi...

Страница 7: ...llow the instructions 1 Disconnect the fixture from AC power 2 Remove the rear cover by loosening the 4 screws 3 Move the wire 1 on the transformer connection block to the position according to the desired voltage 4 EU version Move the wires 2 and 3 on the ballast connection block to the position according to the desired frequency voltage US version Move the wire 2 on the ballast connection block ...

Страница 8: ...ar The projector should be installed outside areas where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calculating working load limits installation material being used and periodic safety inspection of all installation material and the projector If you lack these qualifications do not attempt the installation yourself but ins...

Страница 9: ...e always install a safety rope that can hold at least 10 times the weight of the fixture Pull the safety rope through the mounting bracket and over the trussing system etc Mounting bracket Adjusting screw Floor installation The projector can stand directly on the floor by standing on the removable stand which is mounted with the nut to the projector mount ing bracket Mounting bracket groundplan Me...

Страница 10: ...ower plug on the power cable follow the identification table below The earth has to be connected The occupation of the connection cables is as follows Cable EU Cable US Pin International Brown Black Live L Light blue White Neutral N Yellow Green Green Earth Do not connect the projector to a dimmer system DANGER TO LIFE Before taking into operation for the first time the installation has to be appr...

Страница 11: ...e first fixture in the DMX chain with the DMX input of the next fixture Always connect output with the input of the next fixture until all fixtures are connected Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120 Ohm resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture Building a master slave chain Con...

Страница 12: ...tandard part of delivery Switch the fixture off before changing the lens Be careful Front lens is heavy If you want to change the front lens follow the instructions 1 Remove the front cover by unlocking the 4 quarter turn screws 2 Remove the lens shielding by unscrewing the 8 screws 3 Remove the fresnel lens by unscrewing the 2 screws 4 Remove the 4 distance rings 5 Place the wide angle lens and s...

Страница 13: ...p 210 229 No function step 230 239 Lamp Off step 240 255 Reserved step 2 2 Colour wheel disabled if CMY macro is active channel 8 7 Continual Positioning In range 0 129 DMX is possible fine colour positioning set value on channel 3 0 Open white proportional 16 Deep red proportional 32 Blue proportional 48 Green proportional 64 Orange proportional 80 CTF 3200K proportional 96 CTF 5600K proportional...

Страница 14: ...ro 9 step 80 87 Macro 10 step 88 95 Macro 11 step 96 103 Macro 12 step 104 111 Macro 13 step 112 119 Macro 14 step 120 127 Macro 15 step 128 135 Macro 16 step 136 143 Macro 17 step 144 151 Macro 18 step 152 159 Macro 19 step 160 167 Macro 20 step 168 175 Macro 21 step 176 183 Macro 22 step 184 191 Macro 23 step 192 199 Macro 24 step 200 207 Macro 25 step 208 215 Macro 26 step 216 223 Macro 27 step...

Страница 15: ...5 Strobe effect from slow to fast proportional 96 127 No function shutter open step 128 143 Opening pulse in sequences from slow to fast proportional 144 159 Closing pulse in sequences from fast to slow proportional 160 191 No function shutter open step 192 223 Random strobe effect from slow to fast proportional 224 255 No function shutter open step 13 11 Dimmer intensity 0 255 Coarse intensity fr...

Страница 16: ...e top side of the projector or via your controller without affecting the rest of the lighting To switch On Off the lamp please refer to Switching On Off the lamp menu LAMP Note It is also important to note that the discharge lamp is cold restrike types that means that they have to be cold before re strik ing For this reason you have to wait 5 minutes max speed of fan must be adjusted after having ...

Страница 17: ...ous program start in the other slave fixtures All fixtures have a definite synchronized starting point when playing back their programs The number of running program is the same in all slaves and depends on the master s choice menu St AL Every fixture runs its program repeatedly starting the program step No 1 when requested by the master For example If the slave fixture has a shorter program lengt...

Страница 18: ...d AbL MASt SLA 1 SLA 9 SL Ct InFo Po ti totl rSEt La ti totl rSEt LA St totl rSEt tEMP Cur t boAr HEAd Hi tE boAr HEAd rSEt boAr HEAd DM In Func 0 255 F dim 0 255 VErS IC1 r IC3 L PErS dM Pr Mod 1 Mod 2 LA Pr LA Au On Off d L OF On Off dM On On Off dM OF On Off LA dE 0 1 90 s ...

Страница 19: ...A bLc On Off In Po Func 0 255 F dim 0 255 Stor dF SE LAMP On Off MAn M PrE C Colo Co 01 Co 10 dimr dim 0 dim C MAn C Func 0 255 F dim 0 255 tESt St AL Audi On Off Auto Off tESt PrG 1 PrG 2 PrG 3 PLAY tESt PrG 1 PrG 2 PrG 3 Edit PrG 1 PrG 2 PrG 3 St 01 St 99 P End 1 99 S tim 0 1 25 5 s COPY ...

Страница 20: ...20 rESE SPEC LA Ad Zoom 0 255 CodE AdJ Func 0 255 F CAL Colo 0 255 dimr 0 255 A rES uPd M OFF On ...

Страница 21: ...e is connected to the master massages SL C 1 SL C 2 SL C3 SL C 9 still round repeat Note This function is available from the master fixture only 9 3 Fixture informations Use this menu to read an useful information about the fixture Po ti Power on time Select this submenu to read the number of operation hours totL The function shows the total number of the operation hours since the ColorMix 575 AT ...

Страница 22: ...e the counter was last reset In order to reset the counter to 0 you have to hold UP and DOWN and press the ENTER HEAd The function shows the maximum temperature of the fixture head inside since the counter was last reset In order to reset the counter to 0 you have to hold UP and DOWN and press the EN TER DM In Readout of DMX values Select this function to read DMX values 0 255 of each channel rece...

Страница 23: ...isplay by 180 d On This function allows you to keep the display on or to turn off automatically 2 minutes after last pressing any button on the control panel d Int Select this function to adjust the display intensity 20 min 100 max Mi SE Microphone sensitivity Select this function to adjust the microphone sensitivity from 1 maximum to 20 minimum If the sensitivity is correctly adjusted the upper s...

Страница 24: ...tESt The option will start built in test program PrG 1 The option will start created program No 1 PrG 2 The option will start created program No 2 PrG 3 The option will start created program No 3 Note If the fixture operates in the controller mode DMX controller is connected and any program from this menu is selected in this case the fixture will not respond to the DMX controller after switching o...

Страница 25: ...peration AdJ Effect adjustment By this function you can calibrate and adjust the effects to their standard right positions Disconect the DMX controller from the fixture and select AdJ menu The display shows step by step effects by which you can adjust the fixture to the required position before the function calibration DMX controller must be disconnected When the positioning is finished select F C...

Страница 26: ...everal minutes to perform software update If the option Incremental Update isn t checked all processors will be updated including processors with the same software version If you wish to update only later versions of processors enable the Incremental Update check box Avoid interrupting the process Update status is being displayed in the list window When the update is finished the line with the tex...

Страница 27: ...pears if the lamp lighting sensor is failed Please contact your dealer Caution The message is disabled if the lamp light sensor function En Sn is switched Off Po Er This message will appear if the fixture was shortly disconnect from the main MA Er Master error The message informs you that the fixture was addressed as a master and DMX signal is connected to its DMX input Disconnect the DMX controll...

Страница 28: ...n 3 freely programmable programs 99 steps each Digital serial input DMX 512 2 DMX channel presettings 11 or 14 channels Rigging Stands directly on the floor with removable stand Mounts horizontally or vertically with mounting bracket Vertical head adjusting range 135 Temperatures Maximum ambient temperature ta 40 C Maximum housing temperature tB steady state 80 C Minimum distances Min distance fro...

Страница 29: ... sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed DANGER TO LIFE Disconnect from the mains before starting maintenance operation It is essential that the fixture is kept clean and that dust dirt and smoke fluid residues must not build up on or within the fixture Other wise the fixture s ...

Страница 30: ...ng screwdriver from the housing anti clockwise Step 2 Remove the old fuse from the fuseholder Step 3 Install the new fuse in the fuseholder Step 4 Replace the fuseholder in the housing and fix it Should you need any spare parts please use genuine parts If the power supply cable of this device will be damaged cable firmly connected with the device it has to be replaced by authorized distributor onl...