ROBAND CHOC1 Скачать руководство пользователя страница 14

 

 

 

Page: 11 

 

 

APPENDIX A 

RESIDUAL CURRENT DEV

ICES (RCD’S) 

Also  known  as  Earth  Leakage  Protection  systems  an  RCD  is  a  protective  device 
that  automatically  disconnects  the  active  conductors  of  a  circuit  when  an  earth 
leakage current reaches a predetermined value. 
Although  RCD’s  are  mandatory  in  domestic  installations,  and  in  the  final  sub-
circuits  of  residential-type  areas,  the  Australian  Standards  quote  that  the 
requirement of an RCD does “not apply to a socket-outlet…..for the connection of 
fixed electric cooking appliances, such as ranges, ovens or hotplates” 

In installations that are neither Domestic nor Residential-type, AS/NZS 3000 2.5.3.3 
s

tates that RCD’s are needed only in situations where equipment may represent an 

increased risk of electric shock to the user, and there are many special comments 
related to the use of heating elements. 

AS/NZS3000  2.5.2  gives  the  following  warnings  that  should  have  been  taken  into 
consideration when an RCD circuit was installed. 

 

To  avoid  unwanted  tripping  due  to  leakage  currents  and  transient 

disturbances, care should be taken to ensure that the sum of the leakage 
currents of electrical equipment on the load side of an RCD is less than 
1/3 of its rated residual current

To  avoid  excessive  leakage  current  causing  unwanted  tripping  where 

socket-outlets are protected by one RCD having a rated residual current 
not greater than  30mA, consideration  should be  given to the  number  of 
socket-outlets  protected  and  the  nature  of  electrical  equipment  likely  to 
be connected to the socket-outlets. 

 

Tubular  elements  (such  as  those  used  in  this  unit)  reaching  temperatures  greater 
than 110°C are subject to moisture absorption and therefore earth leakage current 
generation.    Should  the  installation  and  use  of  this  unit  trip  an  RCD  the  unit  will 
need to be run on a circuit without an RCD (as mentioned above) for approximately 
30-60  minutes,  after  which  time  the  elements  should  have  dried  out  and  the 
machine should function normally.   If you are unable to locate a circuit without an 
RCD  please  contact  your  supplier,  or  if  you  prefer  you  can  contact  Roband  and 
send  the  unit  to  one  of  our  offices  where  we  can  run  the  machine  on  a  suitable 
circuit free of charge (a return freight charge may apply).  

 

 

Содержание CHOC1

Страница 1: ...tainless Steel Elements On Off Switch that Electrically Isolates the Unit from Mains Power Advanced Control Safety Systems Accurate Thermostat Control Safety Over Temp Cut Out These instructions cover...

Страница 2: ...rmission of the publisher The material contained within this document is intended entirely for instructional purposes Roband Head Office Sydney Australia Roband Australia Pty Ltd Tel 61 2 9971 1788 1...

Страница 3: ...N 1 GENERAL PRECAUTIONS 1 PACKAGING 2 COMPLIANCE 2 INSTALLATION 3 OPERATION 4 GENERAL SAFETY 5 CLEANING CARE MAINTENANCE 6 TROUBLESHOOTING 7 SPECIFICATIONS 7 CIRCUIT DIAGRAM 8 EXPLODED DIAGRAM 9 APPEN...

Страница 4: ...ve been given supervision or instruction concerning the safe use of the appliance by a person responsible for their safety These machines are heating units and as with any commercial heating unit the...

Страница 5: ...in regards to Electromagnetic Compatibility As testament to such compliance these units bear the C Tick symbol For further information contact the Australian Communications Authority PO Box 13112 Law...

Страница 6: ...ven As a precaution it is recommended that all non metal bench top surfaces be protected from heat with some form of insulation A piece of masonite sheet metal laminate or similar material would be su...

Страница 7: ...ob to set the desired operating temperature Experience will dictate the best temperature for the particular chocolate being prepared For good results with couverture chocolate we recommend the followi...

Страница 8: ...ne is operating and take care to avoid contact with hot surfaces Use gloves or some other form of protection when handling the Bain Marie National Standards exist outlining the positioning spacing and...

Страница 9: ...he element and tank Do not use a metal scourer In some areas hard water may cause a residue to build up on the surface of the tank and element This should remove to prevent any corrosion to the tank a...

Страница 10: ...hermostat fails and the machine temperature rises above 90 C the thermal cut out will automatically deactivate the power To reset the Thermal Cut out disconnect power from the appliance allow to cool...

Страница 11: ...OC2 TS Thermostat NOTE This circuit diagram has been provided for reference and to assist qualified service and repair agents only Under no circumstances should a person not suitably qualified attempt...

Страница 12: ...Page 9 EXPLODED DIAGRAM MODEL CHOC1...

Страница 13: ...Page 10 MODEL CHOC2...

Страница 14: ...rents and transient disturbances care should be taken to ensure that the sum of the leakage currents of electrical equipment on the load side of an RCD is less than 1 3 of its rated residual current T...

Страница 15: ...will be met by this company This company reserves the right to reject a claim for warranty if it is not completely satisfied with the circumstances under which it occurred and any costs incurred for f...

Страница 16: ...LEADING PRODUCTS AVAILABLE PLUS PIE FOOD WARMERS DRINK MIXERS HIGH PERFORMANCE DEEP FRYERS VITAMIX BLENDERS GRILLMAX TOASTERS NOAW Slicers Manufactured Imported in Australia by Authorised Distributor...

Отзывы: