4.1.9 E-Sim

This terminal support E-Sim which could improve the product stability and to prevent the card slot is
loosen or the SIM is removed.

4.2

Extention/Optional Functions

4.2.1 Light Sensor

Built in high sensitive light sensor module, it could detect the light changes from dark to light and
wake up the terminal to send alarm, this function is for detecting the door open alarm purpose.

4.2.2 Motion Detect

Built in high sensitive, low consumption G-sensor to detect whether the equipment is in motion or
static status and providing the real time moving data.

4.2.3 Temperature and humidity detect

The temperature and humidity detection interface is reserved inside the device, and the digital

temperature and humidity sensor can be connected to detect the temperature and humidity in the
container in real time.

Содержание LTS-3YT

Страница 1: ...LTS 3YT User manual User Manuel LTS 3YT...

Страница 2: ...7 Backend Specific Commands 7 4 1 8 Blind zone compensation 7 4 1 9 E Sim 8 4 2 Extention Optional Functions 8 4 2 1 Light Sensor 8 4 2 2 Motion Detect 8 4 2 3 Temperature and humidity detect 8 Chapte...

Страница 3: ...LTS 3YT User manual 1 Chapter One Product Photo...

Страница 4: ...t different needs of customers 3 Low Voltage The working voltage can be decreased to 10 A during sleep mode to make sure the unit would work longer 4 The device supports 4G 3G 2g networks in most part...

Страница 5: ...4G network TDD LTE FDD LTE 3G network WCDMA 2G network GSM GPRS GNSS Support GPS BD Dual mode GPS L1 1575 42MHz C A Code BD B1 1561 098MHz Dimension 205mm 68mm 27mm L W H Weight 200g 5g Waterproof IP6...

Страница 6: ...on includes Position status longitude and latitude GSM Signal Strength GPS numbers battery voltage etc the upload interval can be configured the unit is able to work no less than 365 days 4 1 2 AGPS T...

Страница 7: ...location data according to the preconfigured interval by customer until a stop tracking command is received 4 1 6 Clock mode The terminal could verify the timely wake up time points maximum 4 points c...

Страница 8: ...e terminal to send alarm this function is for detecting the door open alarm purpose 4 2 2 Motion Detect Built in high sensitive low consumption G sensor to detect whether the equipment is in motion or...

Страница 9: ...tion Guide 5 1 Installation diagram Battery Switch SIM card slot Red LED Fast blink GPRS connecting Slow Blink GPRS Connected Solid on Module error Light sensor E SIM Green LED Solid on Position Blink...

Страница 10: ...rts to flash indicating that the terminal is powered on 5 2 3 Parameter setting TCP UDP connection mode setting For example the client s server IP is 119 145 40 64 port number 8881 If it is connected...

Страница 11: ...on function A 1 LBS WIFI mode A 0 GPS position priority default A 3 Examples LBS 1 enter LBS WIFI position mode Switch off GPS 5 3 4 Clock mode Command Format WAKEUP T1 T2 T3 T4 Description Set a mult...

Страница 12: ...e tracking T1 The return interval for entering the tracking mode during exercise the value range is 1 5 minutes T2 Return interval at rest value range 5 43200 minutes or alarm clock format HH MM A 1 Q...

Страница 13: ...er alarm no track A 2 Open tamper alarm track 15 minutes every 300 seconds A 1 Close tamper alarm A 0 Open tamper alarm track 60 minutes every 60 seconds Default A 0 For example FALL 0 Open tamper ala...

Страница 14: ...dby server IP as 119 23 233 52 Port as 6000 communication mode as TCP IP2 www 365qczx com 6000 0 Set standby server domain name as www 365qczx com port as 6000 communication mode UDP IP2 0 0 delete st...

Отзывы: