background image

 
 
 
 

User's Guide

 

 
 

 
 
 
 
 

TCO HDSP / FF

 

 
 

Time Code Option 

 

for HDSP PCI / Fireface 800 

 
 
 
 
 

LTC / SMPTE Reader and Generator 

Video to Word Clock Converter 

Low Jitter Word Clock Regeneration 

 
 
 

 

 

Содержание TCO FF

Страница 1: ...User s Guide TCO HDSP FF Time Code Option for HDSP PCI Fireface 800 LTC SMPTE Reader and Generator Video to Word Clock Converter Low Jitter Word Clock Regeneration...

Страница 2: ...Package Contents 3 3 Hardware Requirements 3 4 Technical Specifications 4 1 TCO FF 4 4 2 TCO HDSP 4 5 Installing the TCO HDSP 5 6 Installing the TCO FF 5 7 Operation and Usage 7 1 TCO FF 7 7 2 TCO HDS...

Страница 3: ...e following TCO FF TCO board with fixed ribbon cable 1 set of screws User s guide TCO HDSP TCO 1 ribbon cable User s guide 3 Hardware Requirements The TCOs can be operated with the following hardware...

Страница 4: ...and NTSC Word Clock In Video In BNC switchable termination 75 Ohm Transformer coupled galvanically isolated input Not affected by DC offsets within the network Signal Adaptation Circuit signal refres...

Страница 5: ...e computer s housing 8 Reconnect all cables including the power cord 6 Installing the TCO FF To install the TCO the Fireface 800 must be opened If you feel unsecure to do so please con sult a technici...

Страница 6: ...are ready to re assemble the Fireface 9 Check that the safety earth wire yellow green is still connected to the cover Then put the cover on and slide it into the aluminum front panel of the Fireface 8...

Страница 7: ...d For synchronization to a video or LTC signal choose Clock Mode AutoSync and TCO as Pre ferred Sync Ref on the main page of the settings dialog All further settings are done on the TCO page Sync Sour...

Страница 8: ...ings are done on the TCO page Sync Source Input select switch for the inputs LTC video and word clock Lock is dispayed as soon as the TCO is able to synchronize on an input signal Also at the bracket...

Страница 9: ...ut the incom ing signal LTC In The time values read from the LTC signal These values are passed unchanged to the application Input State An LTC input signal detection as valid valid is followed by the...

Страница 10: ...Leipziger Strasse 32 D 09648 Mittweida Trademarks All trademarks registered or otherwise are the property of their respective owners RME Ham merfall SyncAlign und SyncCheck sind eingetragene Marken v...

Страница 11: ...icular installation If this equipment does cause harmful interference to radio or television reception which can be de termined by turning the equipment off and on the user is encouraged to try to cor...

Страница 12: ...Bedienungsanleitung TCO 12...