When set to +24, analog inputs comply with
RP 155:2014 - SMPTE Recommended
Practice
.
3.12.1. AD Converter Specifications
Line In 1-32:
• Resolution: 24 bit
• Input level switchable per c24 dBu, +19 dBu, +13 dBu @ 0 dBFS
• Inputs AC coupled, fully symmetrical signal path (servo-balanced)
• Signal to Noise ratio (SNR) @ +24 dBu, 44.1 kHz: 117.0 dB RMS unweighted, 120.7 dBA
• Signal to Noise ratio (SNR) @ +19 dBu: 116.3 dB RMS unweighted, 119.9 dBA
• Signal to Noise ratio (SNR) @ +13 dBu: 114.7 dB RMS unweighted, 118.3 dBA
• Frequency response @ 44.1 kHz, -0.1 dB: 5 Hz – 20.5 kHz
• THD @ -1 dBFS: < -111 dB, < 0.00029%
• THD+N @ -1 dBFS: < -108 dB, < 0.00039 %
• Channel separation: > 110 dB
3.13. MADI Connectors
The rear of the M-32 AD Pro features independent optical and coaxial MADI (AES10-2003) I/O.
Each input receives up to 64 audio channels.
Auto Input
(see Section 9.2.2, “Connecting Two Identical
MADI Signals for Redundancy”) can be activated to treat both inputs as one.
The optical
"subscriber"
or
"square"
connector (
SC
, IEC 61754-4) accepts both simplex and duplex
multimode (MM) fibers of 50 and 62.5µm diameter and up to 2 km length.
The coaxial BNC connector accepts coaxial cables with 75
Ω
impedance.
On the device, the characteristics and state of the signal at either input can be inspected in the
The presence or loss of a signal at either port is indicated on the standby screen if
• the input port is selected as
clock master
, or
• its audio channels are routed in the
OUTPUT
section.
When using the web remote, the characteristics and state of the signal at either input can be inspected
in the
RME M-32 AD Pro User’s Guide
3.13. MADI Connectors |