The inlets are labeled in the sequence they appear when looking from the front of the
device. This helps identifying the active power source on the display.
The
power switch
next to the two inlets internally disconnects the line connection of the C14 inlets to
the power supplies. Ground and neutral will remain connected.
Lockable IEC plugs
The inlets can be used with special IEC power cords that have a lockable connector. Please contact a
local distributor to purchase these power cords if needed.
3.11. Analog Line Input Connectors
The rear of the M-32 AD Pro features four 25-pin D-sub connectors labeled "LINE IN" with Tascam®-
pinout.
These analog inputs are servo-balanced, allowing balanced and unbalanced signals to be connected
without a difference in level.
When using unbalanced connections, be sure to connect pin 3 (negative/"cold") to pin 1
(ground), to avoid noise from the unconnected pin 3 input.
3.12. Analog Line Levels
The M-32 AD Pro can be adjusted to the following reference levels:
Reference
0 dBFS
Headroom at
+4dBu
Other RME
devices
+24
+24 dBu
20 dB
-
+19
+19 dBu
15 dB
LoGain
+13
+13 dBu
9 dB
+4 dBu
RME M-32 AD Pro User’s Guide