Handling

General specifications

Power supply 

5 V ± 5%  

RE36 I 35 mA 

 

 

RE36 S 35 mA

Power supply 

24 V ± 10%  

RE36 P 40 mA variant A, 25 mA variant B 

(9-bit versions only) 

RE36 P variant A requires heat sink-typ. 3 W 

 

 

 

RE36 I 50 mA variant A (30 mA – 9bit) 

  

RE36 I variant A requires heat-sink typ 1W

 

 

 

RE36 I 25 mA variant B  

 

 

RE36 V 40 mA 

 

 

RE36 C 50 mA

  

NOTE:

 Current consumption figures  

 

 

 

refer to unterminated encoders. 

Sealing 

 

 

IP53   (IP64/68 options available)

Temperature 

5 V versions RE36 

I/S -25 °C to +85 °C

 

24 V versions RE36 

I/V/C -25 °C to +70 °C 

   (0 

°C to +70 °C variant IB)

 

 

RE36 P -25 °C to +125 °C 

   (0 

°C to +70 °C variant PB)

Humidity

 

Storage  

95% maximum relative humidity  

 

 

(non-condensing) (BS EN 61010-1) 

 

Operating  

80% maximum relative humidity  

 

 

(non-condensing) (BS EN 61010-1)

Acceleration 

  operating  

500 m/s

2   

BS EN 60068-2-7:1993 

 

 

(IEC 68-2-7:1983)

Shock 

non-operating

 

  1000 m/s

2

, 6 ms, ½ sine  

 

 

BS EN 60068-2-27:1993  

 

 

(IEC 68-2-27:1987)

Vibration 

operating

 

 

100 m/s

2

, 55 Hz to 2000 Hz  

 

 

BS EN 60068-2-6:1996 

 

 

(IEC 68-2-6:1995)

Mass

  

Encoder unit 1 m cable (no connector)  

 

 

IP53 side cable 105 g. IP64/68 side cable 128 g

Cable  

Outside diameter 5 mm 

 

 

Maximum cable length 10 m (RE36 P),  

 

 

 

20 m (RE36 I/S/V/C)

Installation guide

RE36D02_01

Issue 1, 13

th

 January 2009

RLS merilna tehnika d.o.o.

Poslovna cona Žeje pri Komendi

Pod vrbami 2

SI-1218 Komenda

Slovenia

T

  +386 1 5272100

F

  +386 1 5272129

E

  [email protected]

www.rls.si

IMPORTANT:

 

Power to RE36 encoders must be supplied from a  

DC SELV supply complying with the essential 

requirements of EN (IEC) 60950 or similar specification.

The RE36 series encoders have been designed to the relevant  

EMC standards, but must be correctly integrated to achieve  

EMC compliance. In particular, attention to shielding arrangements  

is critical. 

EMC compliance

This encoder system conforms to the relevant harmonised European standards for 

electromagnetic compatibility as detailed below.

BS EN 61326

Further information

For further information relating to the installation of RE36 encoders see also the 

RE36 data sheet (part number RE36D01). This can be downloaded from our 

website www.rls.si and is also available from your local representative.

Disclaimer

Considerable effort has been made to ensure that the contents of this document 

are free from inaccuracies and omissions. However, RLS merilna tehnika d.o.o. 

makes no warranties with respect to the contents of this document and specifically 

disclaims any implied warranties. RLS merilna tehnika d.o.o. reserves the right 

to make changes to this document and to the product described herein without 

obligation to notify any person of such changes.

®

A  

  associate company

RE36 series rotary encoders