![RKI Gas Tracer Скачать руководство пользователя страница 137](http://html1.mh-extra.com/html/rki/gas-tracer/gas-tracer_operating-manual_1466731137.webp)
Gas Tracer Operator’s Manual, CSA Version
Using Maintenance Mode • 137
Updating the Alarm Latching Setting
With LATCHING set to ON (factory setting), the Gas Tracer remains in alarm
condition until the alarm condition passes and the POWER ENTER button is
pressed.
With LATCHING set to OFF, the Gas Tracer automatically resets an alarm when
the alarm condition passes.
1. Use the AIR
▲
or (SHIFT)
▼
buttons to display the LATCHING menu item.
2. Press and release the POWER ENTER button. The screen will indicate the
current setting.
3. Use the AIR
▲
or (SHIFT)
▼
button to display the desired setting.
4. Press and release the POWER ENTER button to save the setting and return to
the main menu.
Updating the Alarm Silence Setting
With ALM SLNC set to ON (factory setting), pressing and releasing the RESET
SILENCE button silences the buzzer when the Gas Tracer is in alarm. The LEDs
continue to flash and the display continues to show the alarm. If the alarms are set
up as latching, when the gas concentration falls below the alarm level, pressing
and releasing RESET SILENCE button clears all alarm indications for that alarm.
If an alarm condition occurs, you may still enter Display Mode by pressing the
DISPLAY (ADJ) button. The buzzer will be silenced but the LEDs will continue to
flash and the unit will continue to vibrate. If you return to Measuring Mode and
there is still an alarm condition, the LEDs will continue to flash, the unit will
continue to vibrate, and the buzzer will remain off. Once the condition clears,
press the RESET SILENCE button to clear the alarm indications.
With ALM SLNC set to OFF, you cannot silence the buzzer. If an alarm condition
occurs, and you enter Display Mode, the buzzer will not be silenced and the LEDs
will continue to flash. Upon return to Measuring Mode, if there is still an alarm
condition and the alarms are set up as latching, you must wait until it clears
before you can press the RESET SILENCE button to clear the alarm indications.
MAINTENANCE
LATCHING
On
MAINTENANCE
LATCHING