AirLink 6940XP Operator’s Manual
Specifications
•
8
Specifications
Table 1 lists specifications for the AirLink 6940XP.
Table 1: Specifications
Target Gas
Detection Range
Increment
Haz. Loc.
Alarm Points
(1 / 2 / 3 / 4)*
Ammonia (NH
3
)
0-100 ppm
1 ppm
Cl. 1 Div. 2
12 / 25 / 50 / 100 ppm
0-1,000 ppm
35 / 300 / 300 / 1,000 ppm
Arsine (AsH
3
)
0-1.00 ppm
0.01 ppm
0.2 / 0.5 / 1.0 / 1.0 ppm
Carbon Dioxide (CO
2
)
0-5.0% volume
0.1% volume
Cl. 1 Div. 1
0.5 / 3.0 / 3.0 / 5.0 % volume
Carbon Monoxide (CO)
0-1,000 ppm
1 ppm
1,000 / 1,000 / 1,000 / 1,000
ppm
Chlorine (Cl
2
)
0-10.0 ppm
0.1 ppm
Cl. 1 Div. 2
1 / 3 / 5 / 10 ppm
Chlorine Dioxide (ClO
2
)
0-1.00 ppm
0.01 ppm
0.1 / 0.3 / 0.3 / 1.0 ppm
Combustible Gas
0-100% LEL
1% LEL
Cl. 1 Div. 1
10 / 20 / 50 / 100% LEL
0-100% volume
1% vol.
100 / 100 / 100 / 100%
Ethylene Oxide (EtO)
0-10.0 ppm
1.0 ppm
Cl. 1 Div. 2
1 / 3 / 5 / 10 ppm
Formaldehyde (CH
2
O)
0-10.00 ppm
0.01 ppm
0.5 / 2 / 5 / 10 ppm
Hydrogen
0 - 100% LEL
1% LEL
Cl. 1 Div. 1
10 / 20 / 50 / 100% LEL
Hydrogen Chloride (HCl)
0-20 ppm
1 ppm
Cl. 1 Div. 2
5 / 10 / 10 / 20 ppm
0-100 ppm
5 / 10 / 30 / 100 ppm
Hydrogen Cyanide (HCn)
0-50 ppm
Cl. 1 Div. 1
5 / 10 / 15 / 50 ppm
Hydrogen Fluoride (HF)
0-10.0 ppm
0.1 ppm
Cl. 1 Div. 2
3 / 6 / 6 / 10 ppm
Hydrogen Sulfide (H
2
S)
0-10.0 ppm
0.1 ppm
Cl. 1 Div. 1
1 / 5 / 10 / 10 ppm
0-25 ppm
1 ppm
5 / 10 / 10 / 25 ppm
0-50 ppm
5 / 10 / 10 / 50 ppm
0-100 ppm
10 / 50 / 75 / 100 ppm
0-500 ppm
100 / 200 / 200 / 500 ppm
0-2,000 ppm
100 / 200 / 200 / 2,000 ppm
Nitric Oxide (NO)
0-250 ppm
Cl. 1 Div. 2
25 / 50 / 100 / 250 ppm
Nitrogen Dioxide (NO
2
)
0-20.0 ppm
0.1 ppm
Cl. 1 Div. 2
5 / 10 / 10 / 20 ppm