T3A Transmitter • 39
Return to Factory Default Settings
Returning the T3A to its factory default settings will reset all customization of the device,
including the zero and calibration settings of the sensor element. A factory default does not
change the gas type.
1. If necessary, enter the Product Settings and Configuration menu by pressing and holding
the MENU button for 6 seconds.
2. Press and release the MENU button until the Return to Factory Default screen appears.
T3A Product and Configuration Factory Default Settings
Configuration
Setting
Alarm Test
--
Network ID
5
System Information
--
Zero/Calibration Timer
*Cleared*
Unit Information
--
Background Setting
4
Relay 1: Latching/Auto Reset
Auto Reset
Relay 2: Latching/Auto Reset
Auto Reset
Relay 1: Fail-Safe Setting
No (Off)
Relay 2: Fail-Safe Setting
No (Off)
Calibration Method
Manual
RS-485 Modbus Address Setting
1
RS-485 Modbus Baud Setting
9600 bps
4-20 mA Zero Offset Setting
4.00 mA
4-20 mA Full-Scale Offset Setting
20.00 mA
Contrast
--
T3A Operation Factory Default Settings
Configuration
Setting
Sensor Element Zero
*Cleared*
Sensor Element Calibration
*Cleared*
Sensor Assembly Alarm 1 Setting
10% of Sensor Scale
Sensor Assembly Alarm 1 Increasing/
Decreasing Setting
Increasing
Sensor Assembly Alarm 2 Setting
15% of Sensor Scale
Sensor Assembly Alarm 2 Increasing/
Decreasing Setting
Increasing
Содержание 71-0533
Страница 14: ...14 T3A Transmitter Figure 4 Mounting the T3A ...