VOC Pro Transmitter • 39
Return to Factory Default Settings
Returning the VOC Pro to its factory default settings will reset all customization of the device,
including the zero and calibration settings of the sensor element. A factory default does not
change the gas type.
1. If necessary, enter the Product Settings and Configuration menu by pressing and holding
the MENU button for 6 seconds.
2. Press and release the MENU button until the Return to Factory Default screen appears.
VOC Pro Product and Configuration Factory Default Settings
Configuration
Setting
Alarm Test
--
Network ID
5
System Information
--
Zero/Calibration Timer
*Cleared*
Unit Information
--
Background Setting
4
Relay 1: Latching/Auto Reset
Auto Reset
Relay 2: Latching/Auto Reset
Auto Reset
Relay 1: Fail-Safe Setting
No (Off)
Relay 2: Fail-Safe Setting
No (Off)
Calibration Method
Manual
RS-485 Modbus Address Setting
1
RS-485 Modbus Baud Setting
9600 bps
4-20 mA Zero Offset Setting
4.00 mA
4-20 mA Full-Scale Offset Setting
20.00 mA
Contrast
--
VOC Pro Operation Factory Default Settings
Configuration
Setting
Sensor Element Zero
*Cleared*
Sensor Element Calibration
*Cleared*
Sensor Assembly Alarm 1 Setting
10% of Sensor Scale
Sensor Assembly Alarm 1 Increasing/
Decreasing Setting
Increasing
Sensor Assembly Alarm 2 Setting
15% of Sensor Scale
Sensor Assembly Alarm 2 Increasing/
Decreasing Setting
Increasing