RKC INSTRUMENT PF900 Скачать руководство пользователя страница 1

 

Ramp/Soak Controller 

 

 

IMR02L02-E2

 

This manual describes the basic key operation and mode selection of the PF900/PF901.   
For detailed handling procedures and various function settings, please refer to the following 
separate manuals:   

• 

PF900/PF901 Instruction Manual (IMR02L03-E ) 

 

The above manuals can be download from our website:   
URL: http://www.rkcinst.com/english/manual_load.htm 

  

 

1. PARTS DESCRIPTION 

 

 

RESET RUN  FIX  MAN  HOLD 

STEP R.SET  PTN END 

PF900 

PV 

TM  H:M:S 

SV 

††††‡

 

<<<<<<<<<<

!

 

PTN 

SEG 

OUT1 

8 8

 

8 8

 

2  3  4  5  6  7  8  9  10  11  12  ALM 

DO 

TS 

AT 

MONI 

OUT2 

OUT3 

MODE 

SET 

(1) 

(16) 

(17) 

(15) 

(18) 

(19) 

(20) 

(21) 

(14) 

(13) 

(12) 

(11)

(9)

(8)

(7)

(6)

(5)

(4)

(3)

(2)

(10)

 

 

(1)  Measured value (PV) 

display [Green 

*] 

Displays measured value (PV) or various parameter symbols. 

(2)  TIME display 

 [Orange 

*] 

Displays selected time unit: Hour and Minute (H: M) or Minute 
and Second (M: S). 

(3)  SV/Timer display 

 [Orange 

*] 

Displays Set value (SV), Timer setting time or various 
characters. 

(4)  AT/TS lamp  [Green *]  AT: Flashes when autotuning is activated. 

 

(After autotuning is completed: AT lamp will go out) 

TS: Lights when time signal is turned on. 

(5)  PTN display  [Green *]  Displays the pattern number in the execution: 1 to 99. 
(6)  SEG display  [Green *]  Displays the segment number in the execution: 1 to 99. 
(7)  Gradient state lamp

 [Green 

*] 

Displays the state of program in process: rise, soak and fall.   
The display flashes when the process is in the wait mode. 

(8)  Output lamp  [Green *] 

 

Lights when the output (OUT1 to OUT3) corresponding to 
each lamp is ON. 
Lamp indication becomes as follows for current output and 
voltage current. 
For an output of less than 0 %:     Extinguished 
For an output of more than 0 %:  Lit 

(9) Loader 

communication 
connector 

Setting and monitoring on a personal computer (PC) is 
possible if the controller is connected with our cable to a PC 
via our USB communication converter COM-K-3 (sold 
separately) 

1

Our communication software

 2

 must be installed on the PC. 

(10) 

 Monitor key 

Use to switch the monitor screen. Pressing this key while any 
screen other than the SV setting & Monitor mode screen is 
being displayed returns to the Measured value (PV)/Set value 
(SV) monitor screen. 

(11) 

 

Set key

 

Used for parameter calling up and set value registration. 

(12) 

 

Shift key

 

Shift digits when settings are changed. Used to selection 
operation between modes. 

(13) 

 

DOWN key

 

Decrease numerals. 
To scroll through numbers faster, press and hold the DOWN 
key in the manual mode. 
To turn back to the previous time of the program, press and 
hold the DOWN key in the operation mode. 

(14) 

 

UP key

 

Increase numerals. 
To scroll through numbers faster, press and hold the UP key 
in the manual mode. 
To forward the time of the program, press and hold the UP 
key in the operation mode. 

(15)  Unit display  [Green*]  Displays unit: 

°

C (

°

F) or % 

Lights % for parameters in unit of %. 

(16)  Set lock display 

 [Orange*] 

Lights when the settings are locked. 

(17)  ALM lamp 

[Red]  Lights when alarm (Event or heater break alarm [HBA]) is 

turned ON.   
Confirm the alarm type at the Event monitor display. 

(18)  Digital output lamp 

 [Green*] 

Lights when the digital output (DO1 to DO12) corresponding 
to each lamp is ON. 

(19) Program pattern/ 

Bar graph display 
 [White] 

Displays program patterns or bar graph for manipulated value 
(MV). Red display is selectable at event or self-diagnostic 
error. 

 

PF901: White

 

1

  For the COM-K, refer to COM-K Instruction Manual (IMR01Z01-E

). 

2

  Software name: WinUCI-PF900 (Only available as a download from our website.)

 

 

(20)  State display lamp 

  [Green or Orange] 

RESET: Lights in RESET mode [Orange] ** 
RUN:  Lights in RUN mode [Orange] ** 
FIX: 

Lights in FIX mode [Orange] ** 

MAN:  Lights in MAN mode [Orange] ** 
 

** Other lamps light in green. 

HOLD:  Lights when the HOLD key is valid. [Green] 
STEP:  Lights when the STEP/R.SET key is set to STEP 
 [Green] 
R.SET:  Lights when the STEP/R.SET key is set to R.SET 
 [Green] 
PTN: Lights 

when 

the 

PTN/END key is set to PTN [Green] 

END: Lights 

when 

the 

PTN/END key is set to END [Green] 

(21) 

RESET: Use to switch to RESET (Control stop) mode. 

 

RUN: 

Use to switch to RUN (Program control start) mode. 

 

Direct key 

FIX: 

Use to switch to FIX (Fixed set point control) mode. 

   

MAN:  Use to switch to MAN (Manual control) mode. 

   

HOLD:  Use to stop the process of the program or release the 

hold function. 

  

STEP/R.SET 
STEP:  Use to forward a segment of the program. 
R.SET:  Use to turn back to the previous parameter setting. 

  

PTN/END 
PTN: 

Use to display the execution pattern setting display. 

END:  Use to set or release the Program end when setting 

program. 

 

 

2. PARAMETER SETTING MODE 

2.1 Transfer to Each Mode 

The controller has five different setting modes, and all settable parameters belongs to one of 
them. The following chart show how to access different setting mode. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Input type and range display 

This instrument immediately displays input type symbol and input range following power ON. 
Example: When sensor type is K thermocouple (

200 to 

+

1372 

°

C) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2.2 Parameter Selection within Mode 

 

SV setting & Monitor mode 

It is possible to set SV which is a control target and also to monitor PV, SV, MV, etc.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fix mode:

 

Fixed set point control mode

 

 
 
 

 

 

Parameter setting mode 

It is possible to set any parameter relating to control. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fix mode:

 

Fixed set point control mode

 

 

PF900/PF901

 

Quick Operation 
Manual

 

All Rights Reserved, Copyright 

 2009, RKC INSTRUMENT INC. 

 

 

InP

@$

 

K

RANGE

-200 1372

Symbol 

Unit for input display 
 TC/RTD input:  
   

°

C or 

°

 Voltage/Current input:
  

No display 

Automatically 

(in 2 seconds)

Input range high
Input range low

Input type symbol: 

Symbol

K J T S R E b n

P

TC 

Input type

K J T S R E B N PL

W5ReW26Re 

 

Symbol

U L

PR

PT

JP

V I 

TC RTD 

Voltage Current 

Input type

U L PR40-20

Pt100 JPt100

V mA 

Power ON

LEVEL

000:00 

0

00000

TIME

000:00 

0000

0

Segment level 
[Factory set value: 0] 

Segment time

 

[Factory set value: 0:00]

28

00

0:00 

0000

0

28

PTN.TM 0:00

28

RPT.SG     0

28

RPT.PN     0

28

RPT.PR     0

28

CT1      0

28

CT2      0

28

EV  ooooooo

28

TS oooooooo

28

MV1     0.0

28

MV2     0.0

28

WAIT    OOO

PV/SV monitor 

Pattern remaining time 
monitor 

Segment repeat 
remaining time/ 
execution time monitor 

Pattern repeat time/ 
execution time monitor 

Total pattern repeat 
remaining time/ 
execution time monitor 

Current transformer 1 
(CT1) input value 
monitor 

Current transformer 2 
(CT2) input value 
monitor 

Event state monitor 

Time signal state 
monitor 

Manipulated output 
value 1 (MV1) monitor 

Manipulated output 
value 2 (MV2) monitor 

Wait condition monitor 

For details of the SV setting & Monitor mode, refer to the 

PF900/PF901 Instruction Manual (IMR02L03E- )

Automatically 

(in 2 seconds)

28 

 0:00 

PV/SV monitor 

 

Monitor mode

 

Press the 

 key can be change the 

monitor displays. 

 

Program mode

In PV/SV monitor, press the 

key. The

display goes to the segment level/time setting.

28

00

0:00 

0000

0

PV/SV monitor 

SV

 00000

Set value 
[Factory set value: 0] 

28

 

0

PV/SV monitor 

28

MV 0.0

PV/SV monitor 

 

Fix mode * 

In PV/SV monitor, press the 

key. The

display goes to the set value setting. 

 

Manual mode

 

The 

 key and 

key is used to

manipulate output setting in Manual mode.

 

Executing pattern setting

 

 In PV/SV monitor, press the PTN/END key. 
The display goes to the executing pattern 
setting. 

PV/SV monitor 

28

00

0:00 

0000

0

PTN

 

00001

Press the PTN/END key 

Input type/Input range display 

Operation mode 

Change operation status/
mode such as Program/ 
FIX/Manual/RESET and 
PID/AT, etc. 

SV setting & Monitor mode

 Mode to be selected during 

 normal operation 

 Changes SV, TIME, etc 

 Monitor PV, SV, MV, etc 

Parameter setting mode 

Create program pattern, set the 
parameters such as PID and 
Event, or set the parameters for 
program setting such as the 
time signal. 

Automatically (in 4 seconds)

Power ON 

Press and hold the 

 key 

for 2 seconds or more 

Press and hold the 

 key for 2 seconds 

or more 

Press and hold the 

 

key for 2 seconds or more 

Press the 

 key 

while pressing   
the 

 key 

Press the 

 key while

pressing the 

 key for

2 seconds or more 

Press the 

 key while 

pressing the 

 key for   

2 seconds or more 

Press the 

 key while 

pressing the 

 key for 

2 seconds or more 

Setup setting mode 

In this mode, it is possible to 
set setting items not stored in 
the Parameter setting mode. 
Some parameters are also 
settable in the Engineering 
mode. 

Press the 

 key or 

Press the 

 key while pressing the 

 key 

Parameters in Engineering 

mode are settable only when 

the controller is in RESET 

mode. However, it is possible 

to check only the data even 

in RUN mode.

 

Initial level engineering 

mode 

For details, refer to 

PF900/PF901 Instruction 
Manual (IMR02L03-E )

Engineering mode 

The content relating to the 
specification of this product is 
set. Set meet application 
requirements. For details, refer 
to 

PF900/PF901 Instruction 

Manual (IMR02L03-E )

PID 

 

PID memory 
group setting 
block 

PID.GR

 00001

PID memory group

number 

LBD

GR.1 00000

LBD deadband

 

 

 

EVENT 

 

Event memory 
group setting   
block 

EV.GR

 00001

Event memory group

number 

EV4`

GR.1 -0050

Event 4 set value

(EV4) [low] 

 

 

 

WAIT 

 

Wait memory 
group setting 
block 

WT.GR

 00001

Wait memory group

number 

TM.OUT

GR.1   000:00

Wait time-out set value

 

 

 

TM.SIG 

 

Time signal   
memory group 
setting block 

TS.GR

 00001

Time signal memory 

group number 

01.E.TM

GR.1  000:00

Time signal end time

 

 

 

PRO.MV 

 

Output program 
memory group 
setting block 

P.MV.GR

 00001

Output program memory 

group number 

P.MV3

GR.1 -005.0

Output program value 3

 

 

 

LV.PID 

 

Level PID 
setting block 

LEVL.1

PID 00000

Level PID setting 1 

LEVL.7

PID 00000

Level PID setting 7

 

 

 

RESET 

 

Reset mode   
setting block 

SV

RESET 00000

Set value (SV) in

Reset mode 

EV.GR

RESET 00001

Event memory group 

number in Reset mode

 

 

 

FIX 

 

Fix mode 

*

 

setting block 

SV

FIX 00000

Set value (SV) in

Fix mode 

*

 

EV.GR

FIX 00001

Event memory group 

number in Fix mode 

*

 

 

 

MAN 

 

Manual control 
mode setting 
block 

PID.GR

MAN 00001

PID memory group number

in Manual control mode 

EV.GR

MAN 00001

Event memory group number 

in Manual control mode 

 

 

 

EDIT 

 

Edit block 

COPY

00 ‹ 00

Pattern copy 

CLR

00000

Data clear 

 

 

PR.MEM 

 

Program memory 
group setting 
block 

PTN.NO

 

0000

1

Setting pattern 

number 

SIGNL

 00000

Segment signal

 

 

 

28 

00

0:00 

0000

PV/SV monitor 

 

(2 seconds or more)

PROG 

 

Program 
setting block 

PTN.NO

 

0

1

Setting pattern 

number 

P.MV.GR

      00000

Output program 

memory group number

 

 

 

For details of the Parameter setting mode, refer to the 

PF900/PF901 Instruction Manual (IMR02L03E- )