RKC INSTRUMENT LTM-100 Скачать руководство пользователя страница 1

 

Water-proof   

Handheld Infrared   

Thermometer 

LTM-100 

 
 
 

Instruction Manual 

Read this manual before using the instrument. 

 

 

?

 Relation of Distance   

and Measuring Diameter 

The relation between the distance and measuring diameter is as 
follows.   
The more the distance increases, the larger area is needed.   
For accurate reading, a sufficient measuring area should be 
ensured.   

 

The above measuring diameter is defined as an area which allows 
capture of more than 90% of energy.   

?

 Maintenance 

Measuring Window 

The measuring window applies a waterproof structure (IP67). If 
water-soluble stains adhere to the window, wash the measuring 
window with the tap water. Dry the measuring window well after 
washing. Please note that measurement with the measuring window 
wet will cause inaccurate readings. If oil-soluble stains adhere to the 
measuring window, wipe it with a cloth dipped in the diluted neutral 
detergent and rinse it.   

 

Note

 

Do not use chemical agents such as thinner, benzin or alcohol since 
these may cause a crack or fog on the surface of the measuring 
window, and consequently it may change the infrared radiation 
transmittance of the plastic lens.   

Plastic Lens 

Dust, stains and scratches on the measuring window cause 
inaccurate readings. Wipe such stains off with a soft cloth or cotton 
bud for camera or glasses. To get rid of tough stains, remove the top 
hood(rubber)by drawing it, wipe the lens with a cloth  dipped in the 
diluted neutral detergent and rinse it. After getting rid of the stains, 
put the top hood back to the previous place by putting the projection   
along its edge and the ones on the case together. After putting it, 
make sure of fitting it to the correct position. 

 

?

 Troubleshooting 

Symptoms 

Cause 

Countermeasures 

No display appears 

Batteries have been exhausted or they are not placed 
correctly.   

Replace or place them correctly.   

Laser beam is not emitted or is 

weak. 

Battery voltage is low.   

Measurement is possible. Replace batteries when the laser marker is 

necessary.   

Plastic lens is dirty.   

Clean the plastic lens referring to the “Maintenance” section.   

A heat source nearby affects. 

Shield the heat source by a shielding plate. 

Emissivity is not selected properly. 

If emissivity is unknown, refer to  “Reference” section. Also, measure the 
temperature by a contact type thermometer and select adequate emissivity 

so that temperature of this instrument becomes equivalent to that of the 

contact type thermometer.   

Abnormal reading 

Measuring target area is too small.   

Check the target area and keep a sufficient area for measurement.   

Unstable reading 

Unit is affected by a rapid temperature change.   

Leave the unit for stabilizing its temperature and measure.   

No reading appears but display is 

‘OL.’ 

Out of measuring temperature range.   

Check the target to be measured.   

 
 

 

Caution

 

LTM-100 is one of the portable   
laser applied instruments which   
are regulated by the consumer   
product safety law.   

?

  Do not look into the laser beam.   

?

  Do not aim the laser beam at   

human beings.   

?

  Keep the instrument out of   

children’s reach.   

 

 

Please follow the precautions below for use to keep 
the instrument’s functions proper and to enable 
accurate measurement.   

 

Safety Precautions 

?

 

Do not contact this product with a measuring object.   
This is a contactless thermometer. Contact with a hot section 
may cause unrepairable damages or inaccurate readings.   

?

 

Do not damage the measuring window (plastic lens). 
Do not contact a hard object with the measuring window.   
Do not let a foreign object penetrate the measuring window, 
or drop a hard object on the measuring window.   

?

 

Although this instrument applies a shockproof structure, do 
not give an excessive shock to the instrument.   

?

 

Do not bring the instrument closer to an electrostatic object.   

?

 

Emissivity of this instrument can be selected (0.8 to 1.0). 
When the emissivity setting is different from that of a 
measuring object, an inaccurate reading will occur.   

?

 

The sudden changes of the ambient temperature will cause 
inaccurate readings. Wait a while to let the temperature of the 
instrument stabilize, and then measure.   

?

 

Remove batteries from the instrument, if the instrument is not 
in use for a long period or is put in storage.   

Environmental Precautions 

?

 

Do not use or store the 
instrument in a location 
where the instrument is 
exposed to the direct 
sunlight, dust, lampblack 
and corrosive gas, or where 
the temperature and/or 
humidity is high. Otherwise 
the measuring window gets 
soiled or deteriorated, which 
causes inaccurate readings.   

?

 

As this instrument applies a waterproof structure (IP67), a 
slight wetting will not damage the instrument. When the 
plastic lens is wet, however, wipe the lens carefully so as not 
to scratch it as the wetting condition will cause inaccurate 
readings. 

?

 

Keep the instrument away from an object which radiates a 
strong electromagnetic wave. 

 
 

 

?

 Specifications 

Type 
Measuring Range 
Display Resolution 
Measuring Accuracy 

LTM-100 

?

40 to 300 

?

0.5

?

C. 1

?

C for below 

?

20

?

C and over 100C.   

When the ambient temperature is 25

?

2

?

C and the emissivity 

(

?

) is 1,   

0 to 300

?

C: 

bigger value of either of 

?

1% of the measured 

value 

?

 1dg’t or 

?

2

?

C

?

 1dg’t.   

0 to 

?

30

?

C: 

?

3

?

?

 1dg’t 

below 

?

30

?

C: 

?

5

?

?

 1dg’t 

Repeatability 

within 1

?

C

?

 1dg’t 

Response 

1sec (90% response) 

Measuring Diameter 

?

45mm/500mm (Optical sensitivity:90%) 

Emissivity Settings 

Before shipment: 0.95. The value can be altered between 0.8 
and 1.0 with the slide switch at the lower part of the battery 
compartment (by 0.05 steps). 

Collimation 

Laser beam (650nm 1mW JIS class2) specifies the center.   

Water -Proof Property 

IP67 

Auto Power Off 

If no key is pressed for 30 seconds, the power is shut off 
automatically.   

Shock Proof Property 

This instrument or its function/performance will not be 
damaged even if it is dropped on the vinyl tile floor from 1 
meter high.   

Operating Temperature 

0 to 50

?

Operating Humidity 

90% rH and below (no condensation) 

Storage Temperature 

?

20 to 55

?

C (no condensation)  (Note): In the case of 

long-term storage, the batteries should be removed.   

Battery 

2 AAA alkali cell batteries 

Battery Life 

Approximately 10 hours for continuous use 

Housing material 

ABS (antibacterial) 

Dimension 

120 

?

 60 

?

 54mm (Maximum value for each direction)   

Weight 

Approx. 123g 

Accessories 

2 AAA alkaline cell batteries, instruction manual, strap 

Approved Standard 

CE marking:EMI EN61326 ClassB ,EMS EN61326 Annex C 

Stability:

±

5.0

 under EMC test environment at 25

       

 

Instruction Manual No.   IMR01P01-E1 

 

Hood 

HEAD OFFICE : 16-6, KUGAHARA 5 CHOME OHTA-KU TOKYO 146-8515 JAPAN 
 

PHONE  : 03-3751-9799 ( +81 3 3751 9799 ) 

 

Email 

: [email protected] 

 

FAX 

: 03-3751-8585 ( +81 3 3751 8585 ) 

 

http://www.rkcinst.co.jp/ 