RKC INSTRUMENT CZ-200P Скачать руководство пользователя страница 6

 

IM100CZ08-E9

 

6

4.2 Wiring Method 

 

Do not place magnet relays or any other equipment which causes magnetic disturbance near the output converter.

   

Install the power cable away from the 4-conductor shielded cable.

 

 

„

 

Wiring example of standard type 

 

Wiring with PCT-300 (output converter) 

 

Pressure sensor cable

 

Pressure sensor (CZ-200P) 

SHD (E) 

EXC 

+

 (A) 

EXC 

 (C) 

SIG 

+

 (D) 

SIG 

 (B) 

PCT-300 

Shield

Red

Brown

Blue

Black

12 

13 

14 

15 

16 

Colors

Terminal No. 

Input terminals

 

 

 Wiring with PG500 (pressure indicator) 

 

Pressure sensor cable

 

Pressure sensor (CZ-200P)

 

SHD (E) 

EXC 

+

 (A) 

EXC 

 (C) 

SIG 

+

 (D) 

SIG 

 (B) 

PG500 

Shield

Red

 

Brown

Blue

Black

17 

18 

19 

20 

21 

Colors

Terminal No.

 

Input terminals

 

 

 Wiring with REX-PG410 (pressure indicator) 

 

Pressure sensor cable

 

Pressure sensor (CZ-200P)

 

SHD (E) 

EXC 

+

 (A) 

EXC 

 (C) 

SIG 

+

 (D) 

SIG 

 (B) 

REX-PG410 

Shield

Red

 

Brown

Blue

Black

10 

Colors

Terminal No.

 

Input terminals

 

 

For details on wiring with PCT-300, PG500 or REX-PG410, refer to the relevant instruction manual.   

 

„

 

Wiring example of built-in temperature sensor type (Optional) 

 

Pressure sensor cable

 

Pressure sensor (CZ-200P)

 

SHD (E) 

EXC 

+

 (A) 

EXC 

 (C) 

SIG 

+

 (D) 

SIG 

 (B) 

PCT-300, PG500 or REX-PG410

Shield

Red

 

Brown

Blue

Black

 

Temperature indicator 

(indicating controller)

 

+

 

 

Temperature sensor cable

Red terminal (

+

)

Black terminal (

)

Input terminals 

Colors

Thermocouple connector 

Input terminals

 

 

For details on wiring with the temperature indicator (indicating controller), refer to the relevant instruction manual. 

 

 

 

 

Содержание CZ-200P

Страница 1: ...rned z Tools such as wire wheels or abrasive cloths should never be used to clean the process diaphragm z Dropping the instrument may cause the sensor to break or malfunction z To protect built in precision components from damage handle and install carefully Take care to avoid damage to the diaphragm z Do not wipe or rub the nameplate on the outer case of the resin pressure sensor with a cloth moi...

Страница 2: ...C diaphragm specification is not available 4 The SUPRON diaphragm specification is not available to the range of 5 MPa or less and 150 MPa z Accessories Instruction Manual IM100CZ08 E9 Copper Packing Included in only the Loose nut type thickness t 2 mm If any of the products are missing damaged or if your manual is incomplete please contact RKC sales office or the agent Temperature sensor cable So...

Страница 3: ...the exposed lead pipe is further extended In this case take measures of 1 The effect of heat flow lessens as the installing direction of the sensor changes from the slanting direction Fig 1 B to the horizontal direction Fig 1 C in this order In this case take measures of 1 and 2 if necessary by checking the sensor outer cylinder surface temperature To the relevant manufacturer It is recommended th...

Страница 4: ...rush or bend the thermocouple protecting flexible tube extended from the outer cylinder or the thermocouple plug If so the thermocouple may be damaged to disable temperature measurement or a temperature error may result The temperature sensing block is located about 2 mm within the diaphragm and as a result the measured temperature usually becomes lower than the actual temperature depending on the...

Страница 5: ...pe cover Optional The outer tube and the cable section of the loose nut type and the unified thread type with directly connected cable are the same as the above figure The mounting hole dimensions are the same as those for the standard type PF3 8 JIS B grade Diaphragm Unit mm External dimensions Standard dimensions H A H B H C H D L 120 150 180 210 L1 8 8 8 8 L2 6 6 6 6 L3 60 90 120 150 Weight App...

Страница 6: ...21 Colors Terminal No Input terminals Wiring with REX PG410 pressure indicator Pressure sensor cable Pressure sensor CZ 200P SHD E EXC A EXC C SIG D SIG B REX PG410 Shield Red Brown Blue Black 6 7 8 9 10 Colors Terminal No Input terminals For details on wiring with PCT 300 PG500 or REX PG410 refer to the relevant instruction manual Wiring example of built in temperature sensor type Optional Pressu...

Страница 7: ...setter Monitor plug Zero adjuster Power lamp PCT 300 PWR ZERO mV V MONI 1 Check the rated output mV V described on the nameplated of the CZ 200P This output should be corrected when the cable is extended and then set that value on the rotary switch which is gain setter of the PCT 300 2 The pressure reading zero point is adjusted by the zero adjuster in PCT 300 Perform this zero adjustment after th...

Страница 8: ...al length L 10 m Rated output of the resin pressure sensor e0 1 500 e1 1 500 1 1 96 10 4 10 5 e1 1 499 Set 1 499 to the gain setting portion of the converter 6 3 Correcting Indication Error when the Cable of Another Company is Used The nominal cross sectional area of our cable conductor is 0 5 mm 2 If using a cable from another company the resin pressure sensor s indication value can be corrected ...

Страница 9: ...ation or damage refer to the Main causes on page 9 Main causes These causes may arise independently or in mutual relations Generative cause in operation Overpressure Load pressure exceeding its limit applied Irregular thread engagement The metal pressure sensing surface mechanically scratched or chipped off Metal fatigue The metal sensing surface fatigued by the application of changing or repeatin...

Страница 10: ... diaphragm specification type As to diaphragm temperature 0 15 0 2 of span 10 C Mechanical characteristics Allowable over pressure 120 of span 0 5 MPa 1000 of span 1 MPa 500 of span Limited over pressure 150 of span 0 5 MPa 2000 of span 1 MPa 1000 of span Fixing screw section material SUS630 Lead pipe cover material SUS304 Fixed nut type only Diaphragm material SUS630 HASTELLOY C SUPRON Recommende...

Отзывы: