IM100CZ08-E9
5
Fixed nut type unified thread (CZ-200P-U type)
1/2
−
20UNF
−
2B
φ
14
5.4
+
0.3
0
φ
8
0
−
0.
1
L4
33
16
90
°
1/2
−
20UNF
−
2A
Diaphragm
φ
7.
8
0
−
0.
05
φ
10
.5
0
−
0.
1
φ
38
Connec tor rec eptacle
PRC03
−
23A10
−
7F
Outer cylinder
φ
17
75
13
15 L
5.4
0
−
0.2
6.6
Flat head diameter
of hexagon nut: 23
φ
14
.6
φ
21
φ
18
8 20
4.6
φ
11.
5
90
°
Install the sensor s o that the
diaphragm surface does not
protrude from this surface.
Mounting hole dimensions
(Unit: mm)
External dimensions
※
Fixing screws of sensor finished to JIS B grade.
Install the sensor so that each screw is smoothly
inserted.
Dotted
−
line section:
Dimens ions of lead pipe cover (Optional)
T hermoc ouple
connector
(Optional)
UA
UB
UC
UD
L
120
150
180
210
L4
60
90
120
150
Standard dimensions
W eight
Approx.410 g
Approx.450 g
Approx.490 g
Approx.530 g
* Bending radius of flexible tube: 19 mm or more
Flexible tube * length: Approx. 100 mm
Fixed nut type with directly connected cable (CZ-200P-H type)
When the material of the diaphragm is
SUPRON
, only a fixed nut type with directly connected cable is available.
Thermocouple connec tor
(Optional)
Flat head diameter
of hexagon nut: 23
O uter cylinder
F lexible
jacked cable *
3
30
15
75
*2
L3
L
L1
0
−
0. 2
φ
14
0
−
0.
2
φ
14
.6
L2
φ
10
−
0.
1
−
0.
2
φ
21
φ
38
*1
500
(S tandard)
*1 For S UPR ON with opt ional temperature sensor (thermocouple c onnec tor):
φ
20
For other mat erials wi thout optional temperature s ensor
(thermocouple connector):
φ
26
*2 For S UPR ON: 20
For other mat erials wi th opti onal temperature sens or (t hermoc ouple connect or): 12
For other mat erials wi thout optional temperature s ensor
(thermocouple connector):
15
*3 B ending radius of f lexible jac ked cable: 31 mm or more
*4 B ending radius of f lexible tube (Thermoc ouple prot ec ting): 19 mm or more
Heat s hrinkable
t ube length: 50 mm
Flex ible t ube *
4
length:
Approx. 100 mm
J ack
P RC03
−
32A10
−
7F
Cap
Dot ted
−
line section: Dimensions of lead pipe cover (Optional)
・
The outer tube and the cable section of t he loose nut t ype and the unif ied t hread
type with directly connected cable are t he s ame as t he above f igure.
・
The mount ing hole dimens ions are t he s ame as those for the st andard t ype.
P F3/8
(J IS B grade)
Diaphragm
(U n it: m m )
External dim ensions
S tandard dimensions
H A
H B
H C
H D
L
120
150
180
210
L1
8
8
8
8
L2
6
6
6
6
L3
60
90
120
150
Weight
Approx. 670 g
Approx. 710 g
Approx. 750 g
Approx. 800 g
3.6 Pressure Sensor Installation
1.
Make sure the mounting hole is correctly machined. If installing the pressure sensor into a previously used hole, make sure the hole is
thoroughly cleaned to remove any plastic residue.
2.
Lubricate the threads with a high temperature anti-seize lubricant.
3.
Tighten the hexagon nut part with a torque wrench. When tightening the pressure sensor, always tighten only the hexagon nut part.
•
Fixed nut type (PF3/8 thread: HB, HC type):
30.0 N
・
m
•
Loose nut type (PF3/4 thread: LB, LC type):
60.0 N
・
m
•
Fixed nut type (Unified thread: UB, UC type): 30.0 N
・
m
Tighten the pressure sensor to secure it after the temperature rises.
Do not tighten any block other than the hexagonal nuts, since this may damage the pressure sensor.
4. WIRING
4.1 Wiring Precaution
•
If the pressure sensor is used together with the output converter (PCT-300) or pressure indicator (PG500 or REX-PG410), always connect a
shielded wire to the SHD (E) terminal on the equipment side.
•
Connect a grounding wire to the extruder.
•
For a heat-resistant glass covered cable, the cover is made of fibers. Therefore, the electrical insulation may deteriorate if the cable is
exposed to high humidity or conductive liquid (water, etc.) and cause a pressure indication error. For this reason,
avoid underground wiring
or wiring within electric conduits passing through humid areas as much as possible.
•
To prevent damage to the wire inside, do not bend the flexible jacketed cable or the flexible tube for the thermocouple less than the bending
radius (it should not be shorter than the fixed length) or forcibly pull or twist when handling.