IM100CZ08-E9
2. PRODUCT CHECK
Before using this product, check each of the following:
•
Model code
•
Check that all of the items delivered are complete.
•
Check that there are no scratches or breakage in external
appearance.
Resin pressure sensor
CZ - 200P -
-
-
∗
-
00
(1) Fixing screw type
H: PF3/8 thread
Fixed nut type
Tip
φ
1 0
L: PF3/4 thread
Loose nut type
Tip
φ
1 8
U: 1/2-20UNF thread
Fixed nut type
Tip
φ
7 .8
J: PF1/2 thread
Fixed nut type
Tip
φ
1 0
V: PF1/4 thread
Fixed nut type
Tip
φ
7 .8
W: M14
×
1.5 thread
Fixed nut type
Tip
φ
8
(2) Lead-pipe dimensions
A: Lower part of hexagon nut, L
=
120 mm
B: Lower part of hexagon nut, L
=
150 mm
C: Lower part of hexagon nut, L
=
180 mm
D: Lower part of hexagon nut, L
=
210 mm
(3) Diaphragm section material
S: SUS630
(Standard)
H: HASTELLOY
C
P: SUPRON
(This has a durability for corrosion of equal with the HASTELLOY C )
(4) Diaphragm surface treatment
N: Standard
K: CERAMIC Kanigen plate *
*
SUPRON diaphragm cannot be specified.
(5) Intrinsically safe
N: Standard (For non-explosionproof specification type)
G: Explosionproof specification type (For indoor use)
H: Explosionproof
specification type (For outdoor use)
(6) Pressure range
: Refer to the pressure range code table
(7) Linearize function (Using transducer type)
N: Not
provided
T: PCT-300
-
L
G: PG500 or REX-PG410
(8) Lead-pipe cover
N: Not
provided
C: Provided
(9) Connector specification
N: Standard connector type
P: Special connector type (Water-proof: Equivalent to IP67)
Q: Direct cable connection type
(Water-proof: Equivalent to IP67, Cable length: Standard 3 m)
(10) Temperature sensor
(Equivalent to IEC 60584-2, Tolerance class 2, 1.0: 1982 b)
N: None
K: With built-in K type thermocouple
J: With built-in J type thermocouple
(11) Thermocouple lead wire length
00: Unit (mm) [Standard 100 mm (Code: 0100)]
Pressure range code table
Pressure
range code
Pressure range
(Unit: MPa)
Pressure
range code
Pressure range
(Unit: MPa)
D05P
1, 2, 4
0 to 0.5
020P
0 to 20
001P
2, 4
0 to 1
035P
0 to 35
002P
2, 4
0 to 2
050P
0 to 50
003P
2, 4
0 to 3
070P
0 to 70
005P
2, 4
0 to 5
100P
0 to 100
010P
0 to 10
150P
3, 4
0 to 150
1
Only the loose nut type (L type) is available. However, this range can
be used when combined with the CT-300 (the ZK-872 specification),
PG500 or REX-PG410
2
Only the loose nut type (L type) is available.
3
The HASTELLOY C diaphragm specification is not available.
4
The SUPRON diaphragm specification is not available to the range of
5 MPa or less and 150 MPa.
z
Accessories
•
Instruction Manual [IM100CZ08-E9]
•
Copper Packing
(Included in only the Loose nut type [thickness: t = 2 mm])
If any of the products are missing, damaged, or if your
manual is incomplete, please contact RKC sales office or
the agent.
Temperature sensor cable
(Sold separately)
W-BL-KA-DA-005000: K type thermocouple (Cable length: 5 m)
W-BL-JA-DA-005000: J type thermocouple (Cable length: 5 m)
Sensor connection cable
(Sold separately)
W-AB-N
-PA-5000:
Standard (For non-intrinsic safety)
[Cable length: 5 m]
W-AB-Y
-PB-5000:
Intrinsically safety (Hazardous side)
[Cable length: 5 m]
W-AB-N
-BA-1000: Non-intrinsic
safety (Non-hazardous side)
[Cable length: 1 m]
: Cable cover type
G: Heat-resistant glass coated cable
V: Vinyl coated cable
S: Silicon coated cable
Blind bolt (Sold separately)
This is a bolt to be used to fill the hole on the machine from which a
pressure sensor has been removed. If a blind bolt is necessary,
please contact with our sales staff or the nearest distributor.
3. HANDLING OF THE PRESSURE SENSOR
3.1 Caution in Mounting Pressure Sensors
Observe the following when mounting the pressure sensor.
Mounting environment
•
Ensure that no cooling pipes directly contact the pressure sensor or connector, since the pressure reading accuracy may be affected or the
connector may be damaged.
•
Do not locate any heat source near the pressure sensor or directly expose it to heat. Otherwise, high-temperature deterioration of the sensor
block may occur. If the temperature could rise in the strain gauge block located within the housing, cover possible heat sources with insulation
materials.
•
Do not use the pressure sensor under any of the following environmental conditions:
- Where the sensor is exposed directly to cold air, warm air or hot air.
- Where temperature variations are large.
- Where the sensor is exposed to direct sunlight.
- Where the sensor is directly splashed with water or rain, or the humidity is high.
•
Do not bring magnetic devices such as magnetic relays, etc. near the pressure indicator. Also, keep power lines from the resin pressure
sensor cable.
•
If the pressure sensor is used for screen changer operation, it may suffer an impact during screen changer operation, causing sensor troubles.
In such a case, carefully consider the position and direction when installing the sensor.
(1) (2)
(3) (4) (5) (6)
(7) (8) (9) (10)
(11)