background image

Testing Strategies: 

 

¾

During assembly of the mold check the sensors at each step that might apply pre-loading or side   

 

loads to the sensor; e.g. just after the clamp plate is assembled.

 

¾

After assembling the mold, press on each sensor or ejector pin to ensure that the force can be    

 

applied to the sensor.  While the force is applied, the green or yellow LED will flash. When the    

 

force reaches 10% (2% for piezo) the red LED will stay on.  If no lights flash, the lack of    

 

 

clearance is preventing movement.

 

¾

Piezo sensors will start with the green LED on. If you see a change to yellow or red without  

 

 

pressing on the sensor then the sensor wire is damaged or the connections are dirty. If the green  

 

light does not flash when you apply force to the piezo sensor then the sensor wire is probably    

 

broken or disconnected.

 

¾

If a sensor is “suspect” (yellow LED is On) it may have side loading which can cause it to fail in    

 

operation. If it passes when removed from the mold check the pocket for improper radius or  

 

 

bending of the sensor stem. If it remains suspect when removed from the mold then it should be   

 

returned for re-calibration.

 

¾

If a sensor is “failed” (red LED is On) remove it from the mold assembly and check it again. If it    

 

passes (green) out of the mold then it is being preloaded or side loaded when installed. If it does   

 

not pass then it is permanently damaged and must be returned for repair.

RJG, 

Inc. 

11/20/12 

         Lynx 

Sensor 

Tester

The Lynx Sensor 

Tester works with 

RJG Lynx, strain 

gage, and piezo force 

sensors only.

All LEDs Flashing 

Together: Sensor is not 

communicating.  Electronics 

may be damaged

Green LED On:

Sensor is OK.

Green Flashing:

Pressure is changing

Yellow LED On: 

Sensor offset is ± 5% to ± 

10% (± 1% to ± 2% for piezo)

Yellow Flashing:

Pressure is changing

Red LED On:

Sensor offset is over ± 10% 

(± 2% piezo).

Red LED is Flashing:

Sensor is reporting an

“invalid” condition.  Sensor 

wire damaged (pinched 

or cut) or sensor head 

damaged.

Lynx Sensor Tester Operating Instructions

Pass   Suspect   Fail

Pass   Suspect   Fail

Pass   Suspect   Fail

Pass   Suspect   Fail

Pass   Suspect   Fail

Pass   Suspect   Fail

If the LEDs are flashing in 

sequence, the tester is thinking

Push and 

hold for 

duration of 

the test

Connect directly to each 

sensor to be tested.

Отзывы: