Product Manual | Lynx™ Embedded Sensors LES‑B‑127‑50/125/500/2000
49
TESTING & CALIBRATION (
continued
)
5.
Sensor Operating Temperature
The higher the mold temperature, the
greater the potential for calibration shift.
Below 212 °F (100 °C), calibration usually
remains stable. Sensors running at
300–400 °F (150–200 °C) have a greater
potential for permanent calibration shift
over time.
6.
Visible Sensor Wear
It is normal for the loading nub to show
some wear. However, if the wear pattern
exceeds half the diameter of the loading
nub, the sensor calibration is more likely to
have shifted significantly.
7.
Sensor Zero Offset Shift
The zero offset is the reading of the sensor
with no load applied. While not directly
related to the sensor calibration, the zero
offset does provide indication that the
sensor’s calibration may be suspect.
8.
Abnormal Readings
A sensor reading abnormally high or low
relative to template or to other sensors
can be an indication of a calibration shift.
Before sending the sensor back, check for
other more common causes of erroneous
readings, such as incorrect sensor pocket
dimensions, sensor preload, contamination
in the sensor pocket, and binding
ejector pin due to misalignment, debris/
contamination, or galling.
WARRANTY
RJG, INC. STANDARD THREE‑YEAR
WARRANTY
RJG, Inc. is confident in the
quality and robustness of the
LES‑B‑127‑50/125/500/2000 cavity
pressure sensors, and so are offering a
three‑year warranty on all RJG sensors.
RJG’s cavity pressure sensors are
guaranteed against defects in material
and workmanship for three years from the
original date of purchase. The warranty
is void if it is determined that the sensor
was subjected to abuse or neglect beyond
the normal wear and tear of field use, or
in the event the sensor has been opened
by the customer. This new warranty policy
is the most generous offered in the cavity
pressure sensor industry, with one year
being the most common.
PRODUCT DISCLAIMER
RJG, Inc. is not responsible for the
improper installation of this equipment, or
any other equipment RJG manufactures.
Proper RJG equipment installation does
not interfere with original equipment
safety features of the machine. Safety
mechanisms on all machines should never
be removed.