Verify that the each sensor and static pin pocket is machined correctly.
2.
Protrusion Test (without sensor)
With only the static pin installed, push on the static pin; verify the pin protrudes clearance
above the pin head equal to 1/5th of the part thickness at pin location if part thickness is
less than or equal to 0.06” (1,5 mm), or 0.012” (0,3 mm) if the part thickness at pin location
is greater than 0.06” (1,5 mm).
3.
Flush Test (with sensor)
With the plates disassembled, sensor and pin in place, and cover plate removed, the end
of the static pin should be flush with the plate surface.
MAINTENANCE
Static Pin
Static Pin
Sensor