![RJG Lynx LES-B-127-125 Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/rjg/lynx-les-b-127-125/lynx-les-b-127-125_product-manual_1466485046.webp)
Lynx™ Embedded Sensors LES‑B‑127‑50/125/500/2000 | Product Manual
38
With the ejector pin installed, push on the ejector pin; verify the clearance of 0.012”
(0,3 mm (or 1/5 part thickness)) exists between the bottom of the ejector pin head and the
ejector retainer plate surface.
4.
Flush Test (Full Stack)
With the sensor, ejector, and transfer pin installed, and the ejector plate in the injection
position, fixed towards clamp plate, the ejector pin should be flush with the ejector plate/
cavity surface.
POST‑ASSEMBLY CHECKS
SENSOR INSTALLATION CHECK—CLAMP PLATE (TYPICAL) INSTALLATION (
continued
)
Ejector Retainer Plate
Ejector
Retainer
Plate
Clamp
Plate
Cover
Plate
Ejector
Plate
B Plate or Cavity Insert
B Plate
or
Cavity
Insert
Ejector Pin
Ejector Pin
Transfer Pin
Sensor
Содержание Lynx LES-B-127-125