Lynx™ Strain Gage Button Sensors LS‑B‑127‑50/125/500/2000 | Product Manual
EJECTOR PLATE INSTALLATION
INSTALLATION SPECIFICATIONS (
continued
)
Date: 03.03.2021
Drawn: K.J.Brettschneider
Check: M. Groleau
Design:
Description: LES-B-127-XXXX
Sensor Installation
NOTES:
EJECTOR PIN AND SENSOR CONCENTRICITY MUST BE WITHIN 0.030"
1.
[0.76] OR 10% OF EJECTOR PIN DIA WHICHEVER IS SMALLER.
DO NOT SCALE PRINT
2.
BREAK ALL SHARP EDGES, 0.005 [0.03] R MAX
3.
DIMENSIONS IN INCHES [MM], UNLESS NOTED
4.
TOLERANCES UNLESS SPECIFIED:
5.
XXX = 0.003 [0.08]
XX = 0.01 [0.3]
ANGLES = ±͠3° 30°
Drawing Title: LES-B-127-XXXX-07
N
N
SECTION N-N
Lynx Connector
Top of Mold
Lynx™ Embedded Sensors (LES-B-127-XXXX) Installation—Ejector Plate Installation
RJG, Inc.
3111 Park Drive
231-947-3111
www.rjginc.com