52 | Troubleshooting
IP address configuration
4. Click
Apply
to apply your settings to the current configuration.
5. Click
Save
to save your settings permanently.
IP address configuration
If you have not configured IP addresses correctly, the SteelHeads can’t connect to each other or to your
network.
Solutions
To verify the IP address has been configured correctly:
•
Ensure the SteelHeads are reachable through the IP address by pinging their primary and in-path
interfaces.
•
Ensure that the SteelHeads in the network can reach each other through their own interfaces.
Connect to the SteelHead CLI. For details, see the
Riverbed Command-Line Interface Reference
Manual
. Enter this command to ping from a specific in-path interface on a SteelHead to another in-
path interface:
ping -f -I <local-steelhead-inpath-ip> -s 1400 <remote-steelhead-inpath-ip>
•
Ensure that the default gateways, both for the SteelHead and for its in-path interfaces, are correct.
•
For physical or virtual in-path installations, verify that the server-side SteelHead can be auto-
discovered by the client-side SteelHead.
Connect to the SteelHead CLI. For details, see the
Riverbed Command-Line Interface Reference
Manual
. Enter the command:
tproxytrace -i inpath0_0 <server-ip-address>:<server-tcp-port>
This causes the SteelHead to generate a fake TCP SYN packet, destined for the specified IP address
and TCP port, and send it to the specified in-path interface. A remote SteelHead should respond if it
sees the SYN packet.
•
Verify that the client-side SteelHead is visible to the server-side SteelHead.
Connect to the SteelHead CLI. For details, see the
Riverbed Command-Line Interface Reference
Manual
. Enter the command:
tproxytrace -i inpath0_0 <client-ip-address>: <client-tcp-port>
Optimize only the following
extensions
Specify a list of extensions you want to include in overlapping opens
optimization.
Optimize all except the
following extensions
Specify a list of extensions you don’t want to include. For example, you
should specify any file extensions that use Enable Applock Optimization.
Control
Description
Содержание SteelHead 5080
Страница 10: ...10 Welcome Contacting Riverbed...
Страница 16: ...16 Riverbed Software Licenses Upgrades and Image Signing Software upgrades and image signing...
Страница 60: ...60 Troubleshooting Network integration checklist...
Страница 90: ...90 CX x70 Desktop Appliance Specifications CX 570 and CX 770 specifications...
Страница 94: ...94 CX x55 Appliance Specifications CX 255 specifications...