Preparing your site for installation
•
SteelHead primary interface
These symptoms can be signs of a duplex mismatch:
•
The Link Duplex alarm triggers.
•
On the Reports > Diagnostics: System Logs page you see errors for sends, receives, cyclic
redundancy checks (CRC), and short sends.
•
You can’t connect to an attached device.
•
You can connect to a device when you choose automatic negotiation, but you can’t connect to
that same device when you manually set the speed or duplex.
•
Slow performance across the network.
For detailed information about checking for duplex mismatches, see
Bypass card interface naming conventions
The interface names for the bypass cards are a combination of the slot number and the port pairs
(<slot>_<pair>, <slot>_<pair>). For example, if a four-port bypass card is located in slot 0 of your
appliance, the interface names are lan0_0, wan0_0, lan0_1, and wan0_1, respectively. Alternatively, if
the bypass card is located in slot 1 of your appliance, the interface names are lan1_0, wan1_0, lan1_1,
and wan1_1, respectively.
For detailed information about installing additional bypass cards, see the
Network and Storage Card
Installation Guide
.
Completing the configuration checklist
Before you begin, consult the
Rack Installation Guide
for detailed information about how to install your
model to a rack.
Содержание SteelHead 5080
Страница 10: ...10 Welcome Contacting Riverbed...
Страница 16: ...16 Riverbed Software Licenses Upgrades and Image Signing Software upgrades and image signing...
Страница 60: ...60 Troubleshooting Network integration checklist...
Страница 90: ...90 CX x70 Desktop Appliance Specifications CX 570 and CX 770 specifications...
Страница 94: ...94 CX x55 Appliance Specifications CX 255 specifications...