52
Upgrade and Maintenance Guide
Replacing CX xx55, EX xx60, DX, and SteelFusion Core
Components
Replacing Disk Drives
3.
Press the release button and pull the drive handle toward you to release the disk drive.
Figure 2-14. Releasing the Disk Drive
4.
Slide the faulty disk drive out of the slot.
Make sure you remove the correct drive.
5.
Open the new disk-drive handle by pressing the release button.
6.
Slide in the new disk drive until it mates with the back connectors in the chassis.
The disk drive LED lights blue when connected.
7.
Press in the disk-drive handle to close.
The new disk drive runs through a self-test automatically. The disk drive automatically begins proper
operation with the other disk drives. You do not need to set up or configure the new disk drive.
Replacing Disk Drives in 2U Appliances
The 2U EX1260 and SteelFusion Core 2000 appliances are equipped with replaceable, hot-swappable disk
drives. You must use approved disk drives. To order disk drives, contact Riverbed Support at https://
support.riverbed.com.
Note:
When you replace disk drives, you must wear a grounded ESD antistatic strap to protect the hardware against
electrostatic discharge. Make sure that the strap makes skin contact prior to handling equipment.
Caution:
Use caution when you remove or replace components; they can become hot to the touch.
To replace a disk drive in the 2U xx60 and SteelFusion Core 2000 appliances
1.
Open the bezel.
“Opening the Bezel” on page 42
.
Содержание SteelCentral NetExpress 470
Страница 10: ...10 Upgrade and Maintenance Guide Preface Contacting Riverbed ...
Страница 40: ...40 Upgrade and Maintenance Guide Replacingxx70 Interceptor9600 andSteelFusionCore3500Components Replacing Fans ...
Страница 68: ...68 Upgrade and Maintenance Guide Replacing CX xx55 EX xx60 DX and SteelFusion Core Components Replacing Fans ...
Страница 90: ...90 Upgrade and Maintenance Guide Replacing SteelHead xx50 Components Replacing Fans ...