Upgrade and Maintenance Guide
47
Replacing Disk Drives
Replacing CX xx55, EX xx60, DX, and SteelFusion Core
Components
Removing Disk Drives in Desktop Appliances
The following desktop appliances are equipped with removable disk drives:
CX255
CX570
CX770
SMC9000
SCC1000
Caution:
When removing or replacing disk drives, be careful not to touch the adjacent power supply unit. Touching the
power supply unit can cause electric shock.
Caution:
Use caution when you remove or replace components; they can become hot to the touch.
To replace the disk drive
1.
Power down the appliance.
2.
Unplug the power cord from the AC circuit.
3.
If necessary, remove the appliance from its mounting rack.
4.
Remove the locking screws on the cover of the chassis. There is one locking screw located at the rear and
two on each side.
Figure 2-8. Removing the Locking Screws
5.
Slide the cover back from the appliance to remove it.
6.
Locate the disk drives in the appliance and use a Phillips screw driver to remove the four screws from
the disk drive casing.