62 | Reference: Appliance Specifications
CX 5080 and CX 7080 specifications
CX 5080 and CX 7080 specifications
This section describes the ports, LEDs, and technical and environmental specifications for the 2U
SteelHead CX 5080 and CX 7080 appliances.
Port locations, LEDs, and buttons
This figure illustrates the front of the appliance, including LEDs and buttons.
Figure A-5. CX 5080 and CX 7080 front panel
This table summarizes the LEDs and buttons on the front of the appliance.
Temperature (storage)
-40° to 149°F (-40° to 65°C)
Relative humidity
20% to 80%, noncondensing (Operating)
10% to 95%, noncondensing (Storage)
Reference
LED/button
Description
1
Power On/Off Button and
Integrated LED
On = Green (System is turned on.)
Sleep State = Green (System is in S1 or S3 sleep state.)
Off = No light (Power is off.)
2
IPMI Warning LED
The IPMI Warning LED shows the current health of the server
system.
Normal = Green (No failures)
Degraded/Warning = Amber (Indicates fan failure, high
temperature, over voltage, or power supply failure.)
Critical = Blinks amber and Green (Indicates a problem that needs
attention, such as optimization service down, no license, or in_path
is not enabled for optimization service.)
3
ID LED
On = Blue (System identified remotely on the server.)
Off = Off (System not identified.)