104 | Installing NICs for SteelHead Virtual Edition Appliances
Configuring bypass cards for Hyper-V Server 2012 R2 and 2016
4. Begin to install the correct driver by completing the following steps:
– Navigate to the host machine’s Control Panel, right-click the adapter you created, and click
Properties
.
– Click
Install
from the vEthernet (mgmt) Properties window
– Select Protocol from the Select Network Feature Type window, then click
Add
.
– Click
Have Disk
from the Select Network Protocol window.
Figure 6-5. Installing the driver software
– Click
Browse
, select the ndisprot.inf file that you downloaded from the Riverbed support site,
then click
OK
.
– The
ndisprot.inf
file installs the correct driver software for the network adapter.
5. Open a command prompt as a System Administrator and enter the following command:
net start disprot
6. Start the
bpctl
service by performing the following tasks:
– From the command prompt, navigate to the directory where the host driver files were extracted.
– Enter the following commands:
.\bpctl.exe install
.\bpctl.exe start
The command prompt displays
ok
after the service successfully starts.
7. Find the index that corresponds with the internal driver by completing the following steps:
– Enter the following command from the command prompt:
.\bpvmctl.exe -e