Riva-flo GP40 Скачать руководство пользователя страница 1

IMPORTANT
Please attach your sales invoice/docket here as proof of purchase should warranty service 
be required.

Please do not return Warranty - Retain for your records. 

Purchased From .............................................................................................. ........................ 

Purchase Date..................................... Serial No.............................. Model No........................

L100169-0

615

© information contained here-in remains the property of Pentair Water Pty Ltd. Any reproduction, 

display, publication, modification or distribution is strictly prohibited without the prior written 

permission of Pentair Water Pty Ltd.

Disclaimer:  Every endeavour has been made to publish the correct details in this owner’s manual. 

No responsibility will be taken for errors, omissions or changes in product specifications. Pentair 

Water reserves the right to change specifications

Pacific    

Pentair Water Australia Pty Ltd

Australia

 

1-21 Monash Drive

 

 

Dandenong,

 Victoria, Australia

 

 

Tel: 1

3

00 

137

 

344

 

 

Email: 

au.

[email protected]

 

 

 

Pentair Water New Zealand Ltd

 

 

Christchurch,

 New Zealand

 

 

Tel: 0800 654 112

 

 

Email: 

nz.sales

@pentair.com

O

WNER’S MANU

AL

Should  you  the  installer  or  owner  be  unfamiliar  with  the  correct 
installation or operation of this type of equipment you should contact 
the  distributor  for  the  correct  advice  before  proceeding  with  the 
installation or operation of this product.

Jet Assisted 

Garden Pump 

GP40

We recommend, for additional protection, 
the  pump  to  be  supplied  from  socket 
outlet  protected  by  a  Residual  Current 
Device  –  RCD  (also  known  as  an  Earth 
Leakage Circuit Breaker – ELCB) with a 
maximum rated residual current of 30mA. 

Содержание GP40

Страница 1: ... specifications Pentair Water reserves the right to change specifications Pacific Pentair Water Australia Pty Ltd Australia 1 21 Monash Drive Dandenong Victoria Australia Tel 1300 137 344 Email au sales pentair com Pentair Water New Zealand Ltd Christchurch New Zealand Tel 0800 654 112 Email nz sales pentair com OWNER S MANUAL Should you the installer or owner be unfamiliar with the correct instal...

Страница 2: ... to an Authorised Pentair Water service agent 3 Warranty service work will be denied or suspended on equipment not readily accessible to service personnel that is products that are behind barriers tiled or bricked in installed in roofs or second story external walls including inaccessible power points 4 Any service of any product which is found to be faulty due to abuse fair wear tear misuse or im...

Страница 3: ... user Who the warranty protects This warranty is valid only for the consumer purchaser What the warranty does not cover 1 Damage deterioration or malfunction resulting from a accident misuse negligence fire water lightning or other acts of nature unauthorised product modification or failure to follow instructions supplied with the product b repair or attempted repair by anyone not authorised by Pe...

Страница 4: ...tlet within 2 metres of the pump if there is not one there already 7 Suction This is the most important part of the installation as errors will cause significant problems for the system in performance and longevity IMPORTANT A gate valve must be installed at the tank outlet 8 Symptom Cause Remedy Pump does not Start No Electricity Ensure that the pump is connected to a live outlet Check Circuit br...

Страница 5: ...t of the pressure controller Open a tap or garden hose nozzle and the pump should start and deliver water When the tap is closed the pump will stop once pressure is built up in the system The system is now working correctly If no water is delivered check the troubleshooting section of this manual and additionally refer to the pressure controller installation and operating instructions packaged wit...

Страница 6: ...serting the plug into the suitable socket outlet Connect the pump using the IEC interconnector to the Minipress before plugging the power supply cord into the socket outlet Ensuring there are no water traces on the connectors push them firmly into each other to ensure intended splash water proof protection This connection shall be separated again only for service purpose and only after the power s...

Отзывы: