2.7.2 TwinBus floor control unit 1 4585
Assembly
Remove the TwinBus device and the supplied components from the packaging.
Activity
Result
Note:
Thermal fuses
Instead of conventional melting fuses the TwinBus power supply unit 1 7573 has two electronic fuses
that interrupt the respective power circuit if an overload occurs. If one of these fuses activates, the
associated voltage indicator LED goes off. Proceed as follows to switch on again:
Switch mains voltage off and leave off for approximately 1 minute.
Remedy short circuit or overload.
Switch mains power supply on again.
The associated voltage indicator LED illuminates again.
* Cut off the cover for connecting to additional devices.
Connections
a, b
Main bus line
V
a
, V
b
Main video bus
a1
Floor control line
V
a
, V
b
Floor bus for video
V
a
, V
b
Camera, door station
NV
power supply unit
TV
Door station
System bus
for supplying additional devices from power supply unit 1 7573
Press "P" and then "Z" until
LD 1 briefly illuminates yellow
#
$
"
!