Rittenhouse Compu-Spray Скачать руководство пользователя страница 1

Compu-Spray  

Instruction Manual  

For Canada 

 

Read All Instructions 

 
 

 

 
 

CAUTION 

 

• 

Follow pesticide label instructions carefully. 

• 

Activate device one to two hours prior to use of yard. 

• 

Switch off unit when people are present. 

• 

Switch off unit when the area is not in use. 

 
 
 
 

www.rittenhouse.ca

 

Содержание Compu-Spray

Страница 1: ...anada Read All Instructions CAUTION Follow pesticide label instructions carefully Activate device one to two hours prior to use of yard Switch off unit when people are present Switch off unit when the area is not in use www rittenhouse ca ...

Страница 2: ...ings You ll Need 5 How Compu Spray Works 5 Parts of Compu Spray and How They Function 6 7 Selecting a Site 8 How to Hang 8 Installation 9 How to Use 10 How to Prevent Spaying in One Direction 11 Care and Maintenance 12 13 Winter Storage 14 At Start of New Season 14 Warranty 15 www rittenhouse ca ...

Страница 3: ...g the risk of heartworm in dogs and encephalitis in horses It will reduce substantially the number of flies The Compu Spray will assist in the control of aphids red spider mites mealy bugs and scales Although you may need to spray intensively by hand to get rid of heavy infestation the Compu Spray should keep the bug population down Limited Warranty Your Compu Spray is guaranteed for one year agai...

Страница 4: ...is against the law to use any insecticide in a manner inconsistent with the label instructions Please read the entire label Use strictly in accordance with label precautionary instructions and directions Compu Spray As An Applicator The tank holds slightly more than a gallon each 30 second spray dispenses approximately 2 fluid ounces of solution the frequency of spraying depends on the wind the ma...

Страница 5: ...to control where and when the insecticide is spread The windsock on the bottom of the Compu Spray senses any wind as low as 3 mph and then the computer takes over When the windsock contactor dwells at one of the six wind switches a fine spray is pumped from the nozzle to be carried by the wind The computer times each spray to approximately 30 seconds CAUTION Follow insecticide label instruction ca...

Страница 6: ...another filter screen not shown inside the tank to protect the pump Liquid Level Gauge 10 When the gauge rod is down the Compu Spray can be refilled with solution Fill Cap 9 When removing the fill cap be careful of the gauge rod and float which are attached to it and must also be removed to fill the tank Pump Motor Electronics 6 not shown these parts are inaccessible in the center section where th...

Страница 7: ...UTION DO NOT place your fingers or anything else into the contactor area The electronic circuits are easily damaged by static electricity Batteries The Compu Spray is powered by 2 batteries one of which 14 is shown being placed into its compartment Each compartment has a Door 22 which is held in place by two Screws 20 and its hooks which fit into Slots 21 Battery Wires 12 In each compartment two w...

Страница 8: ...which the prevailing wind blows toward the area you wish to protect from the mosquitoes How to Hang Compu Spray must be suspended at least 10 feet in a way which prevents it from rotating in the wind This is necessary to preserve its consistent response to the direction of the wind The hanging bracket with 2 pulleys attached is provided as a convenience to hang the Compu Spray to a post When the b...

Страница 9: ... ground The post should be secured at the base by either sinking into the ground or using a 30 inch long post holder spike Attach the cleat to the post on the side of the post not directly under the Compu Spray When hoisting Compu Spray up or down do not stand directly underneath it Keep the cleat high to discourage use by children www rittenhouse ca ...

Страница 10: ... of 45 minutes before any spraying can occur IF the Compu Spray is moved or handled with the switch on after this time has elapsed it will probably spray unexpectedly Therefore the switch should be OFF at all times that it is not hung high in its position for intended use To guarantee protection during the time that it is being hoisted into position the Compu Spray has a built in time delay It can...

Страница 11: ... used to block off a section so that the wand cannot touch it Use a oring or a rubber band over two posts not adjacent but separated by one post Place over the posts nearest the side you want to protect from spray In this way you can effectively prevent the Compu Spray from spraying when the wind blows towards that direction www rittenhouse ca ...

Страница 12: ... connected incorrectly Pumping is too weak Nozzle dribbles Cause if the batteries are a couple of months old they may be too weak or defective to make a good spray Battery voltage does decline with use but high quality batteries should last three months Before giving up be sure to try with a new set of batteries One of the two although new may be a dud No spray but motor runs or spray is solid jet...

Страница 13: ...h Avenue St Catharines Ontario Canada L2R 6P9 Please Note You must obtain an RGA Number Return Goods Authorization Number prior to shipping For units under warranty Rittenhouse will repair and ship back to you at not charge For units not under warranty repairs are charged at 58 00 per hour plus parts and shipping Before returning your Compu Spray be sure to remove the batteries empty the tank rins...

Страница 14: ...h a rag Be sure there is a good spray Turn the switch off Keeping the tank partially full of water lay the Compu Spray on its side and remove the batteries Replace the doors and empty completely Store in a warm and upright position Do Not Allow To Freeze At Start Of the New Season If the instructions for winter storage have been followed the Compu Spray can be returned to service as it was under H...

Страница 15: ...Malathion Compu Spray is not properly washed out before storing Compu Spray is used with incorrect batteries Compu Spray is damaged by dropping Compu Spray s electronics have been damaged by static electricity applied to the wind switch contacts Compu Spray is shipped with Malathion in the tank Compu Spray has been disassembled beyond removal of battery doors and nozzle holder www rittenhouse ca ...