Global Wheel-Lok™ GWL-2300
Owner’s Manual
Rite-Hite
®
22
Publication:
00007-AM-EN 2016-08-08
BASE MICRO CONTROLLER BOARD
POWER BOARD
GWL‐2300
OUTPUTS
OUTPUTS
DIAGNOSTIC I/O WALK THRU SEQUENCE [IF EQUIPPED]
12VDC
RELAY
115/230VAC
IN
SI
DE
R
ED
LI
GH
T [
IS
R]
IN
SI
DE
GR
EE
N L
IG
HT
[I
SG]
CO
RN
ER‐
VU
RE
D
LI
GH
T
[C
VU
RD]
CO
RN
ER
‐V
U
GR
EE
N L
IG
HT
[C
VU
G
RN
]
LE
VE
LE
R‐
VU R
ED
LI
GH
T [
LV
U R
D]
LE
VE
LE
R‐
VU GR
EE
N L
IG
HT
[L
‐V
U GR
N]
PE
DE
ST
RI
AN
‐V
U AMB
ER
[PV
U L
T]
PE
DE
ST
RI
AN
‐V
U
AL
AR
M
[P
VU
A
LM
]
OU
TS
ID
E
RE
D
LI
GH
T
[O
SR
]
OU
TS
ID
E
GR
EE
N
LI
GH
T
[O
SG
]
DO
K‐
LO
K
HO
RN
[H
OR
N]
MW
L A
CT
UA
TO
R
[MW
L A
CT
R]
OUT
SI
DE
A
LA
RM
[M
W
L A
LM
]
UN
ID
OX
IT
C [
UD
IT
C OUT
]
GR
EE
N
LIG
H
IN
TE
RL
OC
K
[G
LT
IT
L]
K1
‐ GR
EE
N L
IG
HT
IN
TE
RL
OC
K
K2
‐
SE
CU
RI
TY
S
YS
TE
M
IN
TE
RF
AC
E
[IF E
Q
UI
PPE
D]
MO
TO
R O
UP
TU
T #1
[M1
/L
OCK
]
MO
TO
R O
UP
TU
T #2
(M2
/U
NL
OCK
)
12
VD
C PO
W
ER
S
UPPL
Y O
K
TERMINAL BLOCK NO.
J7.1
6
J7.1
7
J12.1 J12.2 J12.3 J12.4 J12.6 J12.5 J11.2 J11.1 J7.1
9
J15.2 J15.3 J15.4 J15.5 J9.3
J10.3 J5.4
J5.3 J2.1‐6
STEP
POWER BOARD LEDs
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
LD2
LD1
LD7
MICRO CONTROL BOARD LEDs
LD17 LD19 LD11 LD13 LD18 LD12 LD16 LD14 LD49 LD48 LD15 LD37 LD40 LD20 LD39
LD9
LD10
LD1
LD3
‐
1
DIAGNOSTICS ENTERED
F
F
F
F
F
F
F
F
P
F
C
F
F
F
F
F
F
F
F
T
2
CHECK INSIDE RED
T
F
F
F
F
F
F
F
P
F
F
F
F
F
F
F
F
F
F
T
3
CHECK INSIDE GREEN
F
T
F
F
F
F
F
F
P
F
F
F
F
F
F
F
F
F
F
T
4
CHECK CORNER‐VU RED
F
F
T
F
F
F
F
F
P
F
F
F
F
F
F
F
F
F
F
T
5
CHECK CORNER‐VU GREEN
F
F
F
T
F
F
F
F
P
F
F
F
F
F
F
F
F
F
F
T
6
CHECK LEVELER‐VU RED
F
F
F
F
T
F
F
F
P
F
F
F
F
F
F
F
F
F
F
T
7
CHECK LEVELER‐VU GREEN
F
F
F
F
F
T
F
F
P
F
F
F
F
F
F
F
F
F
F
T
8
CHECK PEDESTRIAN‐VU AMBER
F
F
F
F
F
F
T
F
P
F
F
F
F
F
F
F
F
F
F
T
9
CHECK PEDESTRIAN‐VU ALARM
F
F
F
F
F
F
F
T
P
F
F
F
F
F
F
F
F
F
F
T
10
CHECK OUTSIDE RED LIGHT
F
F
F
F
F
F
F
F
T
F
F
F
F
F
F
F
F
F
F
T
11
CHECK OUTSIDE GREEN LIGHT
F
F
F
F
F
F
F
F
P
T
F
F
F
F
F
F
F
F
F
T
12
CHECK DOK‐LOK HORN
F
F
F
F
F
F
F
F
P
F
T
F
T
F
F
F
F
F
F
T
13
CHECK MWL ACTUATOR AND UNIDOX OUTPUTS
F
F
F
F
F
F
F
F
P
F
F
T
F
T
F
F
F
F
F
T
14
CHECK GREEN LIGHT INTERLOCK OUTPUTS
F
F
F
F
F
F
F
F
P
F
F
F
F
F
T
T
F
F
F
T
15
CHECK K2 RELAY
F
F
F
F
F
F
F
F
P
F
F
F
F
F
F
F
T
F
F
T
16
HORN CHIRPS SIGNALING END OF SEQUENCE
F
F
F
F
F
F
F
F
P
F
C
F
F
F
F
F
F
F
F
T
TROUBLESHOOTING GUIDE
KEY
STEPS
ACTIONS
C ‐ HORN CHIRP
2‐3, 12
CHECK POWER SUPPLY LED & POWER SUPPLY FUSE ON POWER CIRCUIT BOARD
F ‐ OFF
CHECK CONTROL HARNESS CONNECTION AT CHEVRON AND MICRO CONTROLLER BOARDS
P ‐ PULSING / FLASHING
4‐11
CHECK POWER SUPPLY LED & POWER SUPPLY FUSE ON POWER CIRCUIT BOARD
T ‐ STEADY ON
CHECK LIGHT BULB, WIRING AND TERMINAL BLOCK CONNECTIONS
13‐15
CHECK POWER SUPPLY LED & POWER SUPPLY FUSE ON POWER CIRCUIT BOARD
CHECK TERMINAL BLOCK CONNECTIONS
PRESS LOCK TO ADVANCE, UNLOCK TO REVERSE
(REFER TO TROUBLESHOOTING GUIDE IF OUTPUT DOESN’T MATCH)
DIAGNOSTICS
TROUBLESHOOTING
Diagnostics
Diagnostic mode may be entered while the restraint is in
any state. To enter diagnostic mode:
1. Press and hold DIAGNOSTIC button until the horn
chirps (approximately five seconds).
2. Press LOCK button.
3. Press UNLOCK button.
4. The horn chirps and the outside light is flashing RED.
The controls are in the first step of diagnostic mode.
NOTEE:
The outside red light will remain flashing at all
times except Step 10.
5. Start at Step 1 in the Diagnostic Table. If the
equipment Outputs do not match the table, use the
Troubleshooting section.
If no buttons are pressed within a five minute period,
the controls will automatically exit to power up. To
exit the diagnostic mode at any time, press the
DIAGNOSTIC button.