Restraint UNLOCKING, UNLOCK Button Pressed
Barrier travels from the LOCKED position to the STORED
position. Inside light is steady red alerting the operator that an
unsafe condition exists and hook is in transit. Outside light is
flashing red alerting truck driver not to move. If horn sounds go
to FAULT state, otherwise go to STORED.
FAULT State From LOCKING State
Barrier cannot obstruct the R.I.G. This could be due to a R.I.G.
that is located too far toward the rear axle, bent, obstructed or
missing. Inside light is flashing red and horn is pulsing, alerting
the forklift operator that the trailer is not locked. Outside light is
flashing red alerting the truck driver not to move.
If the trailer is parked firmly against the dock bumpers go to
HORN OVERRIDE state. If not, press UNLOCK to clear the
fault, have trailer back up and repeat Restraint LOCKING.
FAULT State From UNLOCKING State
Barrier cannot retract to the STORED position. The barrier
could be caught on the R.I.G. or another part of the trailer.
Inside light is flashing red and horn is pulsing, alerting the
forklift operator that the trailer is not locked. Outside light is
flashing red alerting the truck driver not to move.
Make sure trailer is parked firmly against the dock bumpers. If
not, press LOCK to entrap R.I.G., have trailer back up and
repeat Restraint UNLOCKING.
Figure 19
: Restraint Unlocking
Figure 20
: FAULT State
Содержание VBR-300 Dok-Lok
Страница 6: ...6 RITE HITE VBR 300 DOK LOK Owner s Manual Figure 2 VBR 300 DOK LOK Features...
Страница 22: ...22 RITE HITE VBR 300 DOK LOK Owner s Manual Figure 25 LED Status Chart...
Страница 23: ...RITE HITE VBR 300 DOK LOK Owner s Manual 23 Notes...
Страница 26: ...26 RITE HITE VBR 300 DOK LOK Owner s Manual VBR 300 Hydraulic Parts Figure 27 VBR 300 Hydraulic Parts...
Страница 31: ......