background image

User’s Manual

24 of26

antibiotic medicine. 72 hours after surgical external use erythromycin ointment, also
wipe the repair fluid or the eyebrow fluid to the trouble place and help to deal. In a
week avoid massive diets pungent foods the patient color stabbed deeply also cannot
drink wine.

8.

The beautician should build up the treatment file for the customer.

9.

When the treatment head touch on the skin, the energy will be in weakest. When the
treatment head is apart from the skin around 4~6cm, the energy will be in strongest.

6.2 Purify of Embroider Eyebrow

1.

First finds out if the customer has scar physique, or change skin or allergic skin. If they
are covered eyebrow, or purify of embroider eyebrow, tattoo with other methods
before, then use the weak (low) energy big facular to remove, but cannot remove to get
a bleed.

2.

Before purify of embroider the stabbed eyebrow, should scrape off the eyebrow first.
Set optical frequency at 3-5Hz, the treatment head is apart from the skin from 0-3 cm.

3.

The 1064nm laser is used to purify the black and blue-stabbed eyebrow. If the color
present out after 5-10 minutes, we can purify for the second. Select the stronger energy
to crush the pigment and promotes the organism absorption. Reexamines after 6 weeks,
if the pigment or the light pigment trace is not shed, carry on treat once more.

4.

Purify of embroider pink color tabbed eyebrow may use 532nm wavelength directly.

5.

Purify the scarlet red and brown color eyebrow can use 1064nm wavelength first, then
use the 532nm wavelength again. After 6 weeks, use the 532nm wavelength to carry
on the second treatment.

6.

The treatment interval of 6 weeks between two treatments. Treat periodically until
clean up.

7.

Suggestive number of treatment need: 1-3 times

6.3 Purify of Eyeliner

1.

Must insure strict protection for the eyeball; the damage of eyeball created by laser is
irreversible.

2.

Set light frequency at 3-5Hz, and select low energy, small light spot, the treatment
head is apart from the skin 0-3cm. The operator can use 1cm thick gauze to protect the
eyeball of the patient.

3.

Purify the lower eyeliner request the patient to close eye tightly, and the eyeball see
upwards. The operator suppress the gauze with the index finger, suppress and push the
upper eyelids upwardly, the middle finger pokes the lower eyelid to reveal the eyeliner,
carry on the fast treatment with speed of light 3Hz. Advise the patient if feeling painful,
do not move and tell the doctor to pause.

4.

Purify the upper eyeliner requests the patient to close eye tightly, and the eyeball see
downwards. The operators suppress the gauze with the middle finger, suppress the
eyelid to underneath, the index finger push the upper eyelid upwards to reveals the
eyeliner, and carry on the treatment with speed of light 3Hz.

5.

Do not use the anesthetic as far as possible. After 6 weeks, carry on treats once more to
deep part.

6.

The treatment interval of 6 weeks between two treatments. Treat periodically until
clean up.

Содержание QSW500

Страница 1: ...Risen Beauty Technology Co ltd Add Room619 Building 1 NO 10 Zhuoxiu North Street Fangshan District Beijing 102401 China User s Manual 1 of 26 Q Switched Nd YAG 1064 532nm Laser Treatment System QSW500...

Страница 2: ...afety 10 2 7 Fire Prevention 10 2 8 System Safety 10 2 9 Transport Safety 10 2 10 Safe Marking 11 Chapter 3 Installation 11 3 1 Equipment Detailed List 12 3 2 Installation Requirements 12 3 4 Move 15...

Страница 3: ...reet Fangshan District Beijing 102401 China User s Manual 3 of 26 6 4 Purify Soak Lip and Lips Line 25 6 5 Purify Tattoo and Wound Tattoo 25 6 6 Purify Old age Spot and Nevus 25 6 7 Purify Birthmark a...

Страница 4: ...procedure Operation Operation of the device Maintenance Maintenance information Clinical Application including application range treatment process and side effect Parameters selection Basis of paramet...

Страница 5: ...Device Brief Introduction Model name QSW500 Product name Q Switched Nd YAG Laser System Figure 1 1 shows the device Figure1 1 QSW500 Q Switched Nd YAG Laser System 1 3 Device Structure This device is...

Страница 6: ...st shell 4 Pedal control 5 Key switch 6 LCD control panel 7 Plug of Handpiece Front View of Nd YAG Laser Treatment System Notice It is recommended that only the engineer who is authorized by the manuf...

Страница 7: ...epeat frequency 1 10HZ Lead light method directly output laser The light spot diameter 2 5mm Power supply 90 130V 50Hz 60Hz or 200 260v 50Hz Environment temperature 5 40 Relative humidity 80 Cooling s...

Страница 8: ...y when not in use so as to prevent unauthorized access to the device 2 2 2 Safety Warning Only personnel trained by the distributor are authorized to maintain the inner workings of this device Any man...

Страница 9: ...he laser Note Gauze eye shield and tarsi are all effective in the protecting for the eyes 2 5 1 Laser Light Warning The Nd YAG laser is invisible infrared light Among them The laser of 532nm wavelengt...

Страница 10: ...stible material such as acetone or alcohol near the device If alcohol based products are used to disinfect the laser device ensure that the alcohol has completely evaporated prior to operation Flammab...

Страница 11: ...tion method Key switch The key switch is used shut off power This key is only provided by the manufacturer Please pull out the key after operation Please confirm that the system has been locked Emerg...

Страница 12: ...ith adequate ventilation away from devices that produce heat i e refrigerator 3 2 2 Electrical Requirements Before the Laser leaves the factory it has already been marked the local rated voltage accor...

Страница 13: ...s bag and unscrew the ventilation screw caps According to the following figure Before every treatment please ensure that there is enough water inside of the machine 4 Ensure that the key is in the off...

Страница 14: ...ater slide into the cooling system and then turn off the power 10 If the water circulation run well Then switch off the system It means you can fullyassemble system with handpiece screw on the infusio...

Страница 15: ...r the first time rinse the cooling system with distilled water 3 Ensure that the water level is adequate before treatment to prevent over heating 4 Distilled water is added periodically specially when...

Страница 16: ...the instrument and handle with care which the instrument should be supported by natural damage The markings such as Handle with care No wetness up should be on the box 3 5 2 Environment 1 Environment...

Страница 17: ...in the treatment room must wear the protective filtered glasses supplied 10 Make sure the patient is wearing the opaque protective goggles prior to treatment 11 Avoid looking directly into the intense...

Страница 18: ...18 of26 2 Treatment interface figure 5 2 Laser Energy 1 2000mJ Working frequency 1 10 Hz Return to the first interface Start to work Standby Total shooting numbers Current shooting numbers Reset the c...

Страница 19: ...ers can all be adjusted when there is something wrong with the machine when the seller give the buyer the background setting password 1 Do not point and operate the device elsewhere other than the int...

Страница 20: ...ceeds the required protection temperature the water temperature goes high it will show on the screen at the same time the buzzer will give an alarm and the instrument will cease to work When the tempe...

Страница 21: ...ity 3 The damage of system caused by fire the electric power system breaking down lightning flood disaster blast 5 1 Clean Equipment Clean the outer part of the equipment weekly with soft wet tissue Y...

Страница 22: ...head is leaks If the laser treatment head is damaged please change the laser treatment head or contact the dealer There is a cheep sound in the instrument operation process when pressing preignition T...

Страница 23: ...phage will swallow the function and the transportation function continues long tome The stabbed pigment tissue will became gradually shallow in this period time We suggest the treatment interval of 6...

Страница 24: ...e 532nm wavelength directly 5 Purify the scarlet red and brown color eyebrow can use 1064nm wavelength first then use the 532nm wavelength again After 6 weeks use the 532nm wavelength to carry on the...

Страница 25: ...as same as purify soak eyebrow 3 The bigger area only purify once time then do not purify again as far as possible Avoid the energy gathering to create the skin swelling or the blister 4 The treatmen...

Страница 26: ...y 2 Continuously strike the trouble place with the 1064nm wavelength about 15 minutes 3 The treatment time avoids June July August and September every year 4 The yellow brown spot can be cured by this...

Отзывы: