Installing Bus Devices
Page 48
Note:
For maximum operation stability, it is best NOT to exceed a total of:
300 meters (1000 feet) of wiring from the BZE to the LightSYS panel.
300 meters (1000 feet) of wiring from the BZE to the last bus detector.
When connected to LightSYS the Bus Zone Expanders can be defined to support 32 bus zones.
UP to 4 Bus Zones Expanders can be connected to the LightSYS .
Single Zone Expander
The RISCO RP128EZ01 is a Single Zone Expander that enables to connect any detector to
RISCO system BUS. Using the BUS connection you can ease your installation by connecting
any detector in parallel connections from any point along the wiring route. In addition you
can define any detector with one of the following zone terminations supported by the panel:
NO, NC, EOL, DEOL.
To connect the RP128EZ01 to the LightSYS bus
Note:
Up to 32 Single Zone Expanders can be installed on the LightSYS.
1.
Set the RP128EZ01 ID number (1-32) using DIP switches 1-5.
SW1 (1 - 5): ID switches. Defines the Single BUS Zone Expander ID number
SW1 - 6: Not used
2.
Wire the RP128EZ01 BUS wires Red, Black (COM), Yellow(BUS) and Green (BUS) to
the LightSYS BUS.
Note:
For maximum operation stability, it is best NOT to exceed a total of 300 meters (1000
feet) of wiring from the BZ1 to the LightSY panel or to the BUS Zone Expander