Страница 1: ...user guide PROLIFT...

Страница 2: ...en and fresh wounds bruises or broken skin Stop use and consult your doctor if you experience discomfort during use Do NOT put the pads over any conductive body jewellery Do NOT stick the electrodes t...

Страница 3: ...1 INTRODUCTION Using gentle Electrical Muscle Stimulation EMS PROLIFT helps lift firm and tone targeted areas of the face PROLIFT 1 IN TFAC2 UK 2 0...

Страница 4: ...argeted muscles are shown below ORBICULARIS OCULI Closes the eyelids NASALIS Moves the nostrils ZYGOMATICUS MINOR and ZYGOMATICUS MAJOR and LEVATOR LABII SUPERIOR Work together to control the upper li...

Страница 5: ...3 PROLIFT CONTENTS L R M L R M 1 Hands free adjustable headset 2 Control unit 3 Reusable gel pads 4 3 x AAA batteries 5 Beauty case 1 2 3 4 5...

Страница 6: ...ector cable 1 2 HEADSET 3 CONTROL UNIT 4 Control unit 5 Programme lights 1 4 6 Intensity increase Left Right 7 Mode progamme button 8 Intensity decrease Left Right 9 Power on off button 0 Connector so...

Страница 7: ...ng it is shut firmly in place LOW BATTERY INDICATION When the batteries are running low light 4 will flash when the unit is turned on NOTE The unit will power off after 5 seconds If the unit is left u...

Страница 8: ...ite plastic protective backing DO NOT remove the clear protective film Position the gel pads over the black conductive areas press into place ensuring they fully cover the black conductive areas Now p...

Страница 9: ...olding the headset behind the neck with the cable on your left hand side TIP You may find it useful to use a mirror to see the positioning Slowly bring the headset below the ears and then forward over...

Страница 10: ...s will put undue stress on the headset DO NOT place the gel pads above the cheekbones or too close to the ear DO NOT place the gel pads on the temples or across the throat DO NOT have the cable on you...

Страница 11: ...gramme Selection Increase the intensity level by separately pressing both the left L and right R buttons until you feel a tingling sensation You may need to adjust the gel pad positioning slightly to...

Страница 12: ...intensity or low intensity try the following 1 Moisten gel pads with a small amount of water 2 Ensure skin is clean and freshly washed 3 Replace gel pads To change programme press the M button NOTE t...

Страница 13: ...alternating between the different programmes each day There afterward use as required to maintain good tone As a beginner you should always use the programme and intensity that feels comfortable Best...

Страница 14: ...age Ideal for beginners or as a relaxing warm up or wind down to your ProLift routine PROGRAMME 4 MAINTAIN 4 lights illuminated To be introduced after muscle tone has been built up Maintain is a combi...

Страница 15: ...4 FLASHES AND UNIT TURNS OFF Low battery Replace batteries WEAK PULSE Dry gel pads Moisten gel pads with a small amount of water Low intensity Increase by pressing the buttons Low battery Replace bat...

Страница 16: ...pads last for approximately seven uses If the unit is left unused for a long period of time remove the batteries to prolong their life Do NOT dissemble or repair There are no user serviceable parts i...

Страница 17: ...15 SPECIFICATION Power supply 3 x AAA 1 5V LR03 MN2400 Current Consumption 110mA Battery Life 7 hrs...

Страница 18: ...asElectricalorElectronicequipmentsopleaseensureattheendofthelifeofthisproductand its treatment cartridge they are disposed of in the correct manner in accordance with local authority requirements They...