Rinstrum D841 Скачать руководство пользователя страница 15

D841/D850 Installation Manual 

 

008D-600-150 

Page 15 

Appendix A : Supported Protocols 

The  Protocol  Table  below  lists  the  suggested  corresponding  manufacturer  that  each 
protocol aims to support. Note that compatibility is not guaranteed, and manufacturers may 
change their protocol at any time without notice. 

Protocol 
 

Name 
 

Serial 
Traffic 
light 
support 

Unit 
display 
support 

NTEP 
multi 
zero 
support 

Protocol commonly used 
by indicators from: 

Ranger A 

Yes 

No 

Yes 

Rinstrum, GSE, HBM & PT 

Ranger B 

Yes 

Yes 

Yes 

Rinstrum 

Ranger C 

Yes 

Yes 

Yes 

Rinstrum GSE, HBM & PT 

Ranger D 

Yes 

No 

Yes 

Rinstrum 

PCMODE 

Yes 

No 

No 

Custom software 

RINCMD 

No 

No 

No 

Rinstrum & GSE 

Avery string #7  No 

No 

Yes 

Avery L105 

Gedge C2 

No 

No 

No 

Gedge 

Gedge C3 

No 

No 

No 

Gedge 

10 

A&D  standard 
string 

No 

Yes 

No 

A & D 

11 

AD4531 

No 

No 

No 

A & D 

12 

Toledo 
continuous 

No 

Yes 

Yes 

Toledo 

13 

GSE 

without 

COZ 

No 

Yes 

Yes 

GSE 

14 

GSE with COZ  No 

Yes 

Yes 

GSE 

15 

Schenck 
without DP 

No 

No 

No 

Schenck 

16 

Schenck  with 
DP 

No 

No 

No 

Schenck 

17 

Auto 

control 

string 1 

No 

No 

No 

Auto control PC Software 

18 

Auto 

control 

string 2 

No 

No 

No 

Auto control PC software 

19 

Sartorius 

No 

No 

No 

Sartorius 

20 

Soehnle 
without DP 

No 

No 

No 

Soehnle 

21 

Soehnle 

with 

DP 

No 

No 

No 

Soehnle 

22 

Flintab 

No 

No 

No 

Flintab 

23 

Philips 

No 

No 

No 

Philips 

24 

Condec 

No 

Yes 

Yes 

UMC,  GSE,  Rice  Lake, 
Cardinal, 

Fairbanks, 

Eaton, Transcell 

25 

Bilanciai 
DS410 

No 

No 

No 

Bilanciai 

26 

Systec 

No 

No 

No 

Systec 

40 

Configuration 

N/A 

N/A 

N/A 

Changing settings 

41 

Scrolling 

Yes 

No 

No 

K802 firmware only 

 

Refer 

Remote Display Protocol Manual

 for detailed protocol descriptions. 

 

 

Содержание D841

Страница 1: ... 6 2 4 3 Ethernet Optional 7 2 5 Traffic Light Control D841 8 2 5 1 From Internal 5V DC Source Serial communications connection variant only 8 2 5 2 From an External DC Source Serial and Ethernet communications variants 8 2 6 Setup Command 9 2 6 1 Sending the Setup Command 11 2 7 Scrolling Messages K802 firmware in D841 Only 12 2 8 Mounting Options 12 2 8 1 Wall Mounting 12 2 8 2 Weather Hood Opti...

Страница 2: ...feet at 120 degrees viewing angle Update Rate Dependent on data update rate Operating Environment Temperature 20 to 60 C 4 to 140 F case temperature Humidity 90 RH non condensing Storage 20 to 60 C 4 to 140 F ambient Digital Setup Automatic detection with adjustment via a command string Memory Full non volatile operation Dimensions External Dimensions L x H x D D841 760mm x 150mm x 80mm 30 x 6 x 3...

Страница 3: ...sing labels Symbol Name Description ZERO Indicated when the indicator is displaying Centre Of Zero NET Indicated when the indicator shows NET weight MOTION Indicated when the indicator reading is not stable Brightness Control Adjustable 10 steps and Auto Detect Full Brightness Default Scrolling Messages Available in D841 only using K802 Factory fit Firmware up to 150 characters at slow medium fast...

Страница 4: ...d The complete annunciator section can also be left or right hand justified of the weight string The serial interface supports RS 232 and RS 485 as standard with an Ethernet option also available Facilities for automatic selection of data source and baud rate are also standard The remote displays are individually addressable which allows a single device to send targeted information to multiple dis...

Страница 5: ... seals are broken All connections are made at the external sockets located on the bottom right hand side Ensure power cable is not connected to a live source before terminating the power connector Make sure the environment is dry when terminating to prevent moisture ingress into sealed connectors Disconnect power before opening cable connector 2 3 Power Connection The D841 and D850 remote displays...

Страница 6: ...hould ideally be connected to earth at one end for each of the communications options below As there is no provision for the shield connection at the communications connection end of the display it is recommended the shield be terminated at the indicator source end Figure 5 Shield Earthing 2 4 2 Serial Connection The serial connection is used to transmit data to the remote display A shielded data ...

Страница 7: ...ng cable runs Multi dropping is supported A 120Ω resistor is provided for termination Recommended maximum cable distance for RS485 is 1 200m Figure 8 RS485 Socket connection 2 4 3 Ethernet Optional Confirm the display has the Ethernet option fitted by taking note of the connection label located on the underside near the data input socket The optional Ethernet connection has DHCP enabled by default...

Страница 8: ...d protocols or by digital inputs available on the communication connection socket If the traffic light is set by serial communication the digital input control of the traffic lights will be ignored until the power is cycled Note D850 does not have dedicated traffic lights but will display STOP for Red GO for Green and for both Red and Green inputs 2 5 1 From Internal 5V DC Source Serial communicat...

Страница 9: ...oftware that only send a single string with new data when required the Auto Protocol detect may not display all messages sent To overcome this you can lock the protocol using the configuration string which will force the unit not to search on start up but display first message received The display will try and display all data received when in a locked state even if the protocol does not match Che...

Страница 10: ...Annunciator position 0x30 Left hand annunciators Default 0x30 0x31 Right hand annunciators K801 only 0x32 Left hand with units 0x33 Right hand with units Address Hi MSB of the address value Default 0x30 0 to 9 0x30 to 0x39 Address Lo LSB of the address value Default 0x31 0 to 9 0x30 to 0x39 Time Out Hi MSB of the Time out value in seconds Default 0x30 0 to 9 0x30 to 0x39 Time Out Lo LSB of the Tim...

Страница 11: ...d protocol first to acknowledge the previous changes Send the Reset String via the software or R400 indicator until Display will show OK then reinitialize at default settings Note if the unit is already at default settings then the OK message will not be shown Determine what settings need to be changed as based on the Configuration String Set the suitable options in the software or create a custom...

Страница 12: ...ts provided The outer mounting holes are 8mm in diameter Figure 12 Mounting brackets and optional weather hood 2 8 1 Wall Mounting For wall mounting it is recommended that 6mm or 1 4 bolts and washers be used as a minimum Both Brackets are to be used with mounting hole centres at 250mm 9 8 wide and 200mm 7 9 high Fit top bolts first to support display 2 8 2 Weather Hood Optional The optional weath...

Страница 13: ...Manual 008D 600 150 Page 13 2 8 3 Mounting Plate Optional D841 only The optional mounting plate for the D841 supports VESA RAM and pole mounting Figure 13 VESA RAM and Pole mounting examples Figure 14 Optional mounting plate ...

Страница 14: ... status Check source device ERROR Error The source device is reporting an error in its status as detected in the protocol Check source device No valid data from indicator and unit has timed out Check serial Ethernet input check cables and connections confirm protocol baud data bits are supported then power cycle remote to reset PR 00 If this is being intermittently displayed after the start up seq...

Страница 15: ...ry L105 8 Gedge C2 No No No Gedge 9 Gedge C3 No No No Gedge 10 A D standard string No Yes No A D 11 AD4531 No No No A D 12 Toledo continuous No Yes Yes Toledo 13 GSE without COZ No Yes Yes GSE 14 GSE with COZ No Yes Yes GSE 15 Schenck without DP No No No Schenck 16 Schenck with DP No No No Schenck 17 Auto control string 1 No No No Auto control PC Software 18 Auto control string 2 No No No Auto con...

Страница 16: ...D841 D850 Installation Manual Page 16 008D 600 150 Notes ...

Страница 17: ...D841 D850 Installation Manual 008D 600 150 Page 17 Notes ...

Отзывы: